Ultrasound-Derived External Oblique Muscle Thickness Was Not Associated with Surface EMG Amplitude or Shear Modulus During Progressive Isometric Upper-Limb Loading: An Experimental Study

The aim of this study was to assess whether external oblique muscle (OE) thickness was associated with surface electromyography (sEMG) amplitude and shear modulus under progressively increasing load and to examine the effect of load on these three measures. Thickness and shear modulus of the OE were assessed using an Aixplorer ultrasound system in shear wave elastography mode, while sEMG amplitude was recorded using the eMotion system. Measurements were obtained in a semi-supine position at rest, in the unloaded starting position, and during isometric upper-limb contractions with external loads corresponding to 3%, 6%, 9%, and 12% of body mass. Forty-two healthy adults (21 women and 21 men; age 23.1 ± 1.4 years) participated in the study. Load effects were assessed using Friedman tests, whereas associations were examined using linear mixed-effects models after natural-log transformation of sEMG amplitude and shear modulus. Progressive loading significantly increased OE sEMG amplitude and shear modulus (both p < 0.001). Changes in OE thickness were small despite a significant overall effect of load (p = 0.04; Kendall’s W = 0.06). No significant load × OE thickness interaction was found for either sEMG amplitude (p = 0.417) or shear modulus (p = 0.740). In the additive mixed-effects models, load significantly predicted both outcomes (p < 0.001 for both), whereas OE thickness was not associated with either sEMG amplitude (p = 0.814) or shear modulus (p = 0.475). These findings indicate that ultrasound-derived changes in OE thickness should not be interpreted as direct indicators of muscle activity in the semi-supine position and during the isometric upper-limb loading task examined in this study.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-09-11
DOI
https://doi.org/10.3390/app16189014
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound-Derived External Oblique Muscle Thickness Was Not Associated with Surface EMG Amplitude or Shear Modulus During Progressive Isometric Upper-Limb Loading: An Experimental Study

Paweł Linek, Dawid Węgrzyk, Jan Wierczek
Applied Sciences
Muscle activation and electromyography studies
article

Ultrasound-Derived External Oblique Muscle Thickness Was Not Associated with Surface EMG Amplitude or Shear Modulus During Progressive Isometric Upper-Limb Loading: An Experimental Study

Paweł Linek, Dawid Węgrzyk, Jan Wierczek
article en

Abstract

The aim of this study was to assess whether external oblique muscle (OE) thickness was associated with surface electromyography (sEMG) amplitude and shear modulus under progressively increasing load and to examine the effect of load on these three measures. Thickness and shear modulus of the OE were assessed using an Aixplorer ultrasound system in shear wave elastography mode, while sEMG amplitude was recorded using the eMotion system. Measurements were obtained in a semi-supine position at rest, in the unloaded starting position, and during isometric upper-limb contractions with external loads corresponding to 3%, 6%, 9%, and 12% of body mass. Forty-two healthy adults (21 women and 21 men; age 23.1 ± 1.4 years) participated in the study. Load effects were assessed using Friedman tests, whereas associations were examined using linear mixed-effects models after natural-log transformation of sEMG amplitude and shear modulus. Progressive loading significantly increased OE sEMG amplitude and shear modulus (both p < 0.001). Changes in OE thickness were small despite a significant overall effect of load (p = 0.04; Kendall’s W = 0.06). No significant load × OE thickness interaction was found for either sEMG amplitude (p = 0.417) or shear modulus (p = 0.740). In the additive mixed-effects models, load significantly predicted both outcomes (p < 0.001 for both), whereas OE thickness was not associated with either sEMG amplitude (p = 0.814) or shear modulus (p = 0.475). These findings indicate that ultrasound-derived changes in OE thickness should not be interpreted as direct indicators of muscle activity in the semi-supine position and during the isometric upper-limb loading task examined in this study.

Applied SciencesVol. 16(18)
Akademii Wychowania Fizycznego im. Jerzego Kukuczki w Katowicach (PL)
Good health and well-being
Openalex Percentile: Top 20%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.