Thermodynamic evaluation of abandoned-tunnel-based compressed air energy storage under variable- and constant-pressure operation

The increasing share of renewable energy has intensified the need for efficient large-scale energy storage systems. Compressed air energy storage (CAES) is a promising option, but securing large storage space remains a major challenge. This study proposes a 1.5 MW/3 MWh CAES system using abandoned tunnels and presents a thermodynamic comparison between variable-pressure (VP) and constant-pressure (CP) operation modes. An air-bag-based concept is introduced for CP operation, in which the air bag dynamically changes its volume to maintain stable storage pressure while separating compressed air from tunnel water. Leakage tests of a thermoplastic polyurethane (TPU) air bag at 10 bar yielded a measured permeability of 1750 cm 3 ·mm/m 2 ·day·atm and a leakage rate of approximately 0.28% per hour, providing preliminary experimental support for its use as an air–water separation barrier. Three CP-CAES configurations with water storage volumes of 1293, 2000, and 3000 m 3 were compared with an equivalent VP-CAES system, revealing a clear trade-off between tunnel construction volume and the pump energy required for pressure regulation. At a representative thermal energy storage (TES) discharge temperature of 523.15 K, the RTE of CP-CAES increased from 59.55% to 63.63% as the water storage volume increased, compared with 61.84% for the VP-CAES. When realistic operating discharge temperatures were considered, the effective TES discharge temperatures were estimated to be 519.5 K for the VP-CAES and 533 K for the CP-CAES. Under these conditions, the RTE advantage of CP-CAES over VP-CAES increased with water storage volume, reaching up to 3.50%p. These results indicate that abandoned-tunnel-based CP-CAES can outperform VP-CAES when the water storage volume is sufficiently large to reduce the pump-work penalty.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-09-11
DOI
https://doi.org/10.1016/j.applthermaleng.2026.133161
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic evaluation of abandoned-tunnel-based compressed air energy storage under variable- and constant-pressure operation

Changkook Ryu, Seonghyeon Hwang, Ju-Yeol Ryu, Hyerim Kim et al.
Applied Thermal Engineering
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Thermodynamic evaluation of abandoned-tunnel-based compressed air energy storage under variable- and constant-pressure operation

Changkook Ryu, Seonghyeon Hwang, Ju-Yeol Ryu, Hyerim Kim, Sungho Park, Chulho Ha, Tong Seop Kim, Heeyoon Kim
article en

Abstract

The increasing share of renewable energy has intensified the need for efficient large-scale energy storage systems. Compressed air energy storage (CAES) is a promising option, but securing large storage space remains a major challenge. This study proposes a 1.5 MW/3 MWh CAES system using abandoned tunnels and presents a thermodynamic comparison between variable-pressure (VP) and constant-pressure (CP) operation modes. An air-bag-based concept is introduced for CP operation, in which the air bag dynamically changes its volume to maintain stable storage pressure while separating compressed air from tunnel water. Leakage tests of a thermoplastic polyurethane (TPU) air bag at 10 bar yielded a measured permeability of 1750 cm 3 ·mm/m 2 ·day·atm and a leakage rate of approximately 0.28% per hour, providing preliminary experimental support for its use as an air–water separation barrier. Three CP-CAES configurations with water storage volumes of 1293, 2000, and 3000 m 3 were compared with an equivalent VP-CAES system, revealing a clear trade-off between tunnel construction volume and the pump energy required for pressure regulation. At a representative thermal energy storage (TES) discharge temperature of 523.15 K, the RTE of CP-CAES increased from 59.55% to 63.63% as the water storage volume increased, compared with 61.84% for the VP-CAES. When realistic operating discharge temperatures were considered, the effective TES discharge temperatures were estimated to be 519.5 K for the VP-CAES and 533 K for the CP-CAES. Under these conditions, the RTE advantage of CP-CAES over VP-CAES increased with water storage volume, reaching up to 3.50%p. These results indicate that abandoned-tunnel-based CP-CAES can outperform VP-CAES when the water storage volume is sufficiently large to reduce the pump-work penalty.

Applied Thermal EngineeringVol. 306
Inha University (KR), Korea Electric Power Corporation (South Korea) (KR), Institute for Advanced Engineering (KR), Sungkyunkwan University (KR)
Korea Institute of Energy Technology Evaluation and Planning
Affordable and clean energy
Openalex Percentile: Top 20%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.