Warmed intravenous fluid administration attenuated a reduction in body temperature in anaesthetised horses

Abstract Background Peri‐anaesthetic hypothermia is a well‐documented complication of general anaesthesia and is associated with prolonged recovery, impaired wound healing, and delayed coagulation. Fluid warmers can be used to mitigate heat loss, but there is little evidence supporting their effectiveness in equine anaesthesia. Objectives To determine whether administration of warmed intravenous fluids attenuates heat loss during general anaesthesia in horses. Study Design Prospective, randomised, crossover in vivo experiment. Methods Six healthy adult horses were anaesthetised twice and administered intravenous fluids with the HOTLINE® Blood and Fluid Warmer either activated or inactivated. Body temperature was recorded at four anatomic sites (rectum, nasopharynx, pulmonary artery, and urinary bladder), and fluid temperature was measured in the fluid bag, proximal to the warmer, and distal to the warmer. Linear mixed‐effects models evaluated the effects of warmer status, time, measurement site, and ambient temperature, including relevant interactions, with random intercepts for horse. Results Overall body temperature differed statistically but not clinically meaningfully between warmer conditions; however, warmed fluid administration significantly reduced the rate of temperature decline (time × warmer interaction, β = 0.0038°C/min, SE = 0.001, p < 0.0001). Fluid temperature distal to the warmer increased substantially with warmer activation (warmer × distal interaction, β = 6.86°C, SE = 0.17, p < 0.0001). Ambient temperature strongly influenced body temperature ( χ 2 = 437.83, p < 0.001) and fluid temperature ( χ 2 = 634.2, p < 0.0001). Main Limitations Small sample size; environmental variability; no surgical procedure. Conclusions Although warmed intravenous fluids did not increase body temperature, they attenuated intra‐anaesthetic heat loss. The HOTLINE® Blood and Fluid Warmer increased delivered fluid temperature and provided a modest but measurable protective effect against hypothermia. These findings are the first to demonstrate that warmed fluid administration can slow heat loss in horses under general anaesthesia.

Authors

Institutions

Publication Details

Journal
Equine Veterinary Journal
Published
2026-09-18
DOI
https://doi.org/10.1002/evj.70334
Primary Topic
Thermal Regulation in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Warmed intravenous fluid administration attenuated a reduction in body temperature in anaesthetised horses

Klaus Hopster, Allison Mika, Miranda Starr, Alycia Frampton et al.
Equine Veterinary Journal
Thermal Regulation in Medicine
article

Warmed intravenous fluid administration attenuated a reduction in body temperature in anaesthetised horses

Klaus Hopster, Allison Mika, Miranda Starr, Alycia Frampton, Hope Douglas
article en

Abstract

Abstract Background Peri‐anaesthetic hypothermia is a well‐documented complication of general anaesthesia and is associated with prolonged recovery, impaired wound healing, and delayed coagulation. Fluid warmers can be used to mitigate heat loss, but there is little evidence supporting their effectiveness in equine anaesthesia. Objectives To determine whether administration of warmed intravenous fluids attenuates heat loss during general anaesthesia in horses. Study Design Prospective, randomised, crossover in vivo experiment. Methods Six healthy adult horses were anaesthetised twice and administered intravenous fluids with the HOTLINE® Blood and Fluid Warmer either activated or inactivated. Body temperature was recorded at four anatomic sites (rectum, nasopharynx, pulmonary artery, and urinary bladder), and fluid temperature was measured in the fluid bag, proximal to the warmer, and distal to the warmer. Linear mixed‐effects models evaluated the effects of warmer status, time, measurement site, and ambient temperature, including relevant interactions, with random intercepts for horse. Results Overall body temperature differed statistically but not clinically meaningfully between warmer conditions; however, warmed fluid administration significantly reduced the rate of temperature decline (time × warmer interaction, β = 0.0038°C/min, SE = 0.001, p < 0.0001). Fluid temperature distal to the warmer increased substantially with warmer activation (warmer × distal interaction, β = 6.86°C, SE = 0.17, p < 0.0001). Ambient temperature strongly influenced body temperature ( χ 2 = 437.83, p < 0.001) and fluid temperature ( χ 2 = 634.2, p < 0.0001). Main Limitations Small sample size; environmental variability; no surgical procedure. Conclusions Although warmed intravenous fluids did not increase body temperature, they attenuated intra‐anaesthetic heat loss. The HOTLINE® Blood and Fluid Warmer increased delivered fluid temperature and provided a modest but measurable protective effect against hypothermia. These findings are the first to demonstrate that warmed fluid administration can slow heat loss in horses under general anaesthesia.

Equine Veterinary Journal
University of Pennsylvania (US)
Openalex Percentile: Top 12%
Thermal Regulation in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.