A unified signal-quality assessment framework for synchronized electro-intravascular encephalography and scalp electroencephalography

BACKGROUND: Neurointerventional electrophysiology enables minimally invasive access to near-cortical signals without craniotomy. However, a standardized and interpretable signal-quality evaluation framework for electro-intravascular encephalography (EiEG) is lacking, limiting reproducible reporting and principled comparison with conventional scalp electroencephalography (EEG). METHODS: We proposed a framework quantifying physiological concordance, spectral fidelity, and robustness, and validated it in an ovine EiEG model using a stent-mounted electrode deployed in the superior sagittal sinus over the motor cortex. EiEG and spatially corresponding scalp EEG were synchronously recorded across four repeated 5 min bouts using shared hardware and matched preprocessing. RESULTS: Using the proposed framework in this preparation, we evaluated physiological concordance, spectral fidelity (signal-to-noise ratio (SNR) index), and robustness in simultaneous EiEG and scalp EEG recordings. Concordance was high (Spearman's ρ>0.94). Under the unified SNR definition, the framework quantified overall linear SNR ratios of 2.04 vs Cz and 1.84 vs C1 over 0.5-40 Hz. Across four repeated 5 min recording bouts, EiEG showed greater consistency than scalp EEG, with lower overall-band across-bout coefficient of variation (CV: 0.8% vs 29.8% for Cz and 6.7% for C1) and lower mean absolute relative deviation from bout 1 (1.5% vs 23.6% and 5.4%, respectively). No acute procedure-related complications were observed. CONCLUSIONS: This framework enables interpretable and reproducible evaluation of EiEG signal quality. When applied to this preparation under synchronized recording, EiEG showed high physiological concordance with scalp EEG together with higher spectral fidelity and greater across-bout consistency.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2026-09-11
DOI
https://doi.org/10.1136/jnis-2026-025329
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A unified signal-quality assessment framework for synchronized electro-intravascular encephalography and scalp electroencephalography

Fan Feng, Ying Du, Yudong Ma, Sining Li et al.
Journal of NeuroInterventional Surgery
Anesthesia and Sedative Agents
article

A unified signal-quality assessment framework for synchronized electro-intravascular encephalography and scalp electroencephalography

Fan Feng, Ying Du, Yudong Ma, Sining Li, Gan L, Yahan Duan, Fei Kang, Wenzhi Wang, Feng Duan, Hao Jia
article en

Abstract

BACKGROUND: Neurointerventional electrophysiology enables minimally invasive access to near-cortical signals without craniotomy. However, a standardized and interpretable signal-quality evaluation framework for electro-intravascular encephalography (EiEG) is lacking, limiting reproducible reporting and principled comparison with conventional scalp electroencephalography (EEG). METHODS: We proposed a framework quantifying physiological concordance, spectral fidelity, and robustness, and validated it in an ovine EiEG model using a stent-mounted electrode deployed in the superior sagittal sinus over the motor cortex. EiEG and spatially corresponding scalp EEG were synchronously recorded across four repeated 5 min bouts using shared hardware and matched preprocessing. RESULTS: Using the proposed framework in this preparation, we evaluated physiological concordance, spectral fidelity (signal-to-noise ratio (SNR) index), and robustness in simultaneous EiEG and scalp EEG recordings. Concordance was high (Spearman's ρ>0.94). Under the unified SNR definition, the framework quantified overall linear SNR ratios of 2.04 vs Cz and 1.84 vs C1 over 0.5-40 Hz. Across four repeated 5 min recording bouts, EiEG showed greater consistency than scalp EEG, with lower overall-band across-bout coefficient of variation (CV: 0.8% vs 29.8% for Cz and 6.7% for C1) and lower mean absolute relative deviation from bout 1 (1.5% vs 23.6% and 5.4%, respectively). No acute procedure-related complications were observed. CONCLUSIONS: This framework enables interpretable and reproducible evaluation of EiEG signal quality. When applied to this preparation under synchronized recording, EiEG showed high physiological concordance with scalp EEG together with higher spectral fidelity and greater across-bout consistency.

Journal of NeuroInterventional Surgery
Nankai University (CN), Air Force General Hospital PLA (CN), Tang Du Hospital (CN)
Openalex Percentile: Top 8%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.