Continual cuffless blood pressure monitoring in children: agreement and feasibility compared with ambulatory blood pressure monitoring

BACKGROUND: Cuffless wearable technologies enable continual blood pressure (BP) monitoring and may improve tolerability compared with conventional cuff-based methods. Pediatric data comparing cuffless devices with ambulatory blood pressure monitoring (ABPM) remain limited. METHODS: In this prospective observational study, children with well controlled type 1 diabetes mellitus and normal office BP underwent simultaneous 24-h monitoring using a wrist-worn cuffless optical device and conventional ABPM. Between-method differences were assessed for averaged 24-h, daytime, and nighttime systolic and diastolic BP. Equivalence was evaluated using the two one-sided tests procedure with a prespecified exploratory ± 10 mmHg margin, whereas individual-level agreement was assessed using Bland-Altman analysis. RESULTS: Twenty-one participants were included (mean age 14.7 ± 2.6 years). Mean differences (Aktiia - ABPM) were -4.5 mmHg for 24-h systolic BP and -0.8 mmHg for 24-h diastolic BP. The 90% confidence intervals were fully contained within the ±10 mmHg margin for 24-h and nighttime systolic BP and for diastolic BP across all periods, but not for daytime systolic BP. Bland-Altman analysis showed modest mean bias but wide limits of agreement, particularly for systolic BP. Nocturnal systolic and diastolic BP dipping was attenuated with cuffless monitoring. CONCLUSIONS: In this selected pediatric cohort, continual cuffless BP monitoring was feasible and showed group-level comparability with ABPM for averaged 24-h BP values. However, it should not be considered interchangeable with ABPM for individual clinical decisions or assessment of nocturnal dipping. Larger studies in more diverse pediatric populations are required before broader clinical implementation.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2026-09-11
DOI
https://doi.org/10.1097/hjh.0000000000004445
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Continual cuffless blood pressure monitoring in children: agreement and feasibility compared with ambulatory blood pressure monitoring

Michal Huml, Josef Sykora, Renata Pomahačová, Alexandra Kotková et al.
Journal of Hypertension
Non-Invasive Vital Sign Monitoring
article

Continual cuffless blood pressure monitoring in children: agreement and feasibility compared with ambulatory blood pressure monitoring

Michal Huml, Josef Sykora, Renata Pomahačová, Alexandra Kotková, Jiří Fremuth, Tereza Fremuthová, Karel Fiklík, Stanislav Kormunda
article en

Abstract

BACKGROUND: Cuffless wearable technologies enable continual blood pressure (BP) monitoring and may improve tolerability compared with conventional cuff-based methods. Pediatric data comparing cuffless devices with ambulatory blood pressure monitoring (ABPM) remain limited. METHODS: In this prospective observational study, children with well controlled type 1 diabetes mellitus and normal office BP underwent simultaneous 24-h monitoring using a wrist-worn cuffless optical device and conventional ABPM. Between-method differences were assessed for averaged 24-h, daytime, and nighttime systolic and diastolic BP. Equivalence was evaluated using the two one-sided tests procedure with a prespecified exploratory ± 10 mmHg margin, whereas individual-level agreement was assessed using Bland-Altman analysis. RESULTS: Twenty-one participants were included (mean age 14.7 ± 2.6 years). Mean differences (Aktiia - ABPM) were -4.5 mmHg for 24-h systolic BP and -0.8 mmHg for 24-h diastolic BP. The 90% confidence intervals were fully contained within the ±10 mmHg margin for 24-h and nighttime systolic BP and for diastolic BP across all periods, but not for daytime systolic BP. Bland-Altman analysis showed modest mean bias but wide limits of agreement, particularly for systolic BP. Nocturnal systolic and diastolic BP dipping was attenuated with cuffless monitoring. CONCLUSIONS: In this selected pediatric cohort, continual cuffless BP monitoring was feasible and showed group-level comparability with ABPM for averaged 24-h BP values. However, it should not be considered interchangeable with ABPM for individual clinical decisions or assessment of nocturnal dipping. Larger studies in more diverse pediatric populations are required before broader clinical implementation.

Journal of Hypertension
Charles University (CZ)
Openalex Percentile: Top 21%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.