Multi-Fault Diagnosis in Twisted-Pair Cables of Networked Control Systems Using Transferometry

In networked control systems, power line communication technique is used to transfer data over existing energy cables. A soft fault degrades the integrity of the signal without impacting the system behaviour. This work develops a transferometry-based method for detecting, localising, and estimating the severity of two simultaneous soft faults in such cables. A soft fault is modelled as a series impedance, and the transmission coefficient (TC) is computed from the ABCD cascade model of the cable. We prove that, under unmatched terminations, the time-domain TC exhibits a five-pulse signature whose peak positions and amplitudes map directly to the two fault positions and their individual severities. A residual signal constructed from this signature yields closed-form estimators for the fault positions and their combined severities; individual fault severities require a bounded nonlinear least-square fit, valid for approximately symmetric, known terminations. We further show that the method extends to n simultaneous soft faults under a combined soft-fault condition, with the (2n+1)-pulse pattern verified in simulation for n∈{1,2,3,4}. A Monte Carlo study using correct localisation probability as the detection criterion establishes a practical SNR threshold of 25 dB; fault-separation resolvability shows intermittent, sidelobe-driven degradation rather than a single threshold. Simulations on a measured 24 AWG cable, extrapolated beyond its characterised band, confirm reliable two-fault diagnosis under additive noise, with reliable multi-fault performance demonstrated for n=1,2, presented as a numerical proof of concept on this extrapolated cable model rather than a characterisation confirmed by measurement over the full simulated band.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-09-11
DOI
https://doi.org/10.3390/eng7090471
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Multi-Fault Diagnosis in Twisted-Pair Cables of Networked Control Systems Using Transferometry

Abdel Karim Abdel Karim
Eng—Advances in Engineering
Power Line Communications and Noise
article

Multi-Fault Diagnosis in Twisted-Pair Cables of Networked Control Systems Using Transferometry

Abdel Karim Abdel Karim
article en

Abstract

In networked control systems, power line communication technique is used to transfer data over existing energy cables. A soft fault degrades the integrity of the signal without impacting the system behaviour. This work develops a transferometry-based method for detecting, localising, and estimating the severity of two simultaneous soft faults in such cables. A soft fault is modelled as a series impedance, and the transmission coefficient (TC) is computed from the ABCD cascade model of the cable. We prove that, under unmatched terminations, the time-domain TC exhibits a five-pulse signature whose peak positions and amplitudes map directly to the two fault positions and their individual severities. A residual signal constructed from this signature yields closed-form estimators for the fault positions and their combined severities; individual fault severities require a bounded nonlinear least-square fit, valid for approximately symmetric, known terminations. We further show that the method extends to n simultaneous soft faults under a combined soft-fault condition, with the (2n+1)-pulse pattern verified in simulation for n∈{1,2,3,4}. A Monte Carlo study using correct localisation probability as the detection criterion establishes a practical SNR threshold of 25 dB; fault-separation resolvability shows intermittent, sidelobe-driven degradation rather than a single threshold. Simulations on a measured 24 AWG cable, extrapolated beyond its characterised band, confirm reliable two-fault diagnosis under additive noise, with reliable multi-fault performance demonstrated for n=1,2, presented as a numerical proof of concept on this extrapolated cable model rather than a characterisation confirmed by measurement over the full simulated band.

Eng—Advances in EngineeringVol. 7(9)
American University of the Middle East (KW)
Affordable and clean energy
Openalex Percentile: Top 20%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multi-Fault Diagnosis in Twisted-Pair Cables of Networked Control Systems Using Transferometry — Abdel Karim Abdel Karim · Eng—Advances in Engineering (2026) | TGRS Research Map | TGRS