Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers

BACKGROUND: Over-ear headphones are a growing source of allergic contact dermatitis (ACD). Identifying well-known and new culprit sensitizers in such products is challenging because of a lack of labelling and limited cooperation from manufacturers. OBJECTIVES: To report potential skin sensitizers in occupationally-used headphones from patients attending an occupational allergy clinic. PATIENTS AND METHODS: The over-ear headphones from two octylisothiazolinone (OIT)-allergic patients with ear ACD were chemically analysed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). RESULTS: UPLC-MS/MS confirmed the presence of OIT, but also other biocides (1,2-benzisothiazolin-3-one, cetylpyridinium chloride), rubber accelerators (zinc dibenzyldithiocarbamate, 1,3 diphenyl guanidine, 1,3 di-O-tolyguanidine, tetramethylthiuram disulfide, tetraethylthiuram disulfide), acrylates (isobornyl acrylate [IBOA]), plasticizers (triphenyl phosphate [TPP], tricresyl phosphate), oxidizers (benzoylperoxide) and organic solvent (dimethylformamide [DMF]). CONCLUSIONS: Over-ear headphones may contain reproductive toxicant such as DMF, as well as several sensitizers, including TPP, OIT and IBOA. Under the EU REACH Regulation, the use of DMF is restricted, TPP is listed as a Substance of Very High Concern, whereas OIT and IBOA are not subject to specific restriction. Across both occupational and non-occupational settings, the use of over-ear headphones may cause contact dermatitis due to exposure to various chemical substances. Our findings may serve to explain these and future cases.

Authors

Institutions

Publication Details

Journal
Contact Dermatitis
Published
2026-09-10
DOI
https://doi.org/10.1111/cod.70246
Primary Topic
Contact Dermatitis and Allergies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers

Goël Fenech, Catherine Champmartin, Eddy Langlois, Eric Pelletier et al.
Contact Dermatitis
Contact Dermatitis and Allergies
article

Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers

Goël Fenech, Catherine Champmartin, Eddy Langlois, Eric Pelletier, Lynda Bensefa‐Colas, Marie‐Noëlle Crepy
article en

Abstract

BACKGROUND: Over-ear headphones are a growing source of allergic contact dermatitis (ACD). Identifying well-known and new culprit sensitizers in such products is challenging because of a lack of labelling and limited cooperation from manufacturers. OBJECTIVES: To report potential skin sensitizers in occupationally-used headphones from patients attending an occupational allergy clinic. PATIENTS AND METHODS: The over-ear headphones from two octylisothiazolinone (OIT)-allergic patients with ear ACD were chemically analysed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). RESULTS: UPLC-MS/MS confirmed the presence of OIT, but also other biocides (1,2-benzisothiazolin-3-one, cetylpyridinium chloride), rubber accelerators (zinc dibenzyldithiocarbamate, 1,3 diphenyl guanidine, 1,3 di-O-tolyguanidine, tetramethylthiuram disulfide, tetraethylthiuram disulfide), acrylates (isobornyl acrylate [IBOA]), plasticizers (triphenyl phosphate [TPP], tricresyl phosphate), oxidizers (benzoylperoxide) and organic solvent (dimethylformamide [DMF]). CONCLUSIONS: Over-ear headphones may contain reproductive toxicant such as DMF, as well as several sensitizers, including TPP, OIT and IBOA. Under the EU REACH Regulation, the use of DMF is restricted, TPP is listed as a Substance of Very High Concern, whereas OIT and IBOA are not subject to specific restriction. Across both occupational and non-occupational settings, the use of over-ear headphones may cause contact dermatitis due to exposure to various chemical substances. Our findings may serve to explain these and future cases.

Contact Dermatitis
Inserm (FR), Université Paris Cité (FR), Sorbonne Paris Cité (FR), Assistance Publique – Hôpitaux de Paris (FR), Hôtel-Dieu de Paris (FR), Centre de Recherche Épidémiologie et Statistique (FR), Institut National de Recherche et de Sécurité (FR)
Openalex Percentile: Top 8%
Contact Dermatitis and Allergies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.