Enhancing Fluorescence Detection Accuracy for Aromatic Pollutants in Aquatic Environments via Absorption Spectroscopy-Based Inner Filter Effect Compensation

To address the quantitative distortion problem caused by the primary internal filtration effect (PIFE) resulting from coexisting substances in the fluorescence detection of aromatic pollutants, this study proposes a multi-component concentration quantification correction model that integrates transmittance absorbance and lateral (90°) fluorescence intensity. Using styrene as the target analyte and anthracene/phenanthrene as representative interferents, by establishing a coupled framework of excitation light decay dynamics and fluorescence emission, the nonlinear PIFE problem was transformed into a linear regression task. The experimental results show that: under the coexistence of anthracene and phenanthrene, the model reduces the detection deviation of styrene from 40 to 63% to within 10%, and the correction accuracy of the three-component mixed system is increased by 3–5 times. This work provides a theoretical framework for fluorescence quantitative analysis in complex systems, and also offers a new method for high-precision online monitoring of aromatic organic pollutants.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-09-10
DOI
https://doi.org/10.3390/chemosensors14090201
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Fluorescence Detection Accuracy for Aromatic Pollutants in Aquatic Environments via Absorption Spectroscopy-Based Inner Filter Effect Compensation

Sijie Lin, Lijin Zhong, Dawei Zhang, Jie Bao
Chemosensors
Water Quality Monitoring and Analysis
article

Enhancing Fluorescence Detection Accuracy for Aromatic Pollutants in Aquatic Environments via Absorption Spectroscopy-Based Inner Filter Effect Compensation

Sijie Lin, Lijin Zhong, Dawei Zhang, Jie Bao
article en

Abstract

To address the quantitative distortion problem caused by the primary internal filtration effect (PIFE) resulting from coexisting substances in the fluorescence detection of aromatic pollutants, this study proposes a multi-component concentration quantification correction model that integrates transmittance absorbance and lateral (90°) fluorescence intensity. Using styrene as the target analyte and anthracene/phenanthrene as representative interferents, by establishing a coupled framework of excitation light decay dynamics and fluorescence emission, the nonlinear PIFE problem was transformed into a linear regression task. The experimental results show that: under the coexistence of anthracene and phenanthrene, the model reduces the detection deviation of styrene from 40 to 63% to within 10%, and the correction accuracy of the three-component mixed system is increased by 3–5 times. This work provides a theoretical framework for fluorescence quantitative analysis in complex systems, and also offers a new method for high-precision online monitoring of aromatic organic pollutants.

ChemosensorsVol. 14(9)
Southern University of Science and Technology (CN), Beijing Academy of Quantum Information Sciences (CN), University of Science and Technology Beijing (CN)
Life below water
Openalex Percentile: Top 10%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.