AI-assisted high-density near-infrared spectroscopy system for cerebral oxygen saturation measurement in a porcine ischemia model

Abstract Stroke is one of the leading causes of mortality and is characterized by a sudden interruption of cerebral perfusion, resulting in neurological impairment. Especially in large-vessel occlusion (LVO), the absence of timely reperfusion therapy can lead to severe ischemic injury, causing permanent disability or death. Near-infrared spectroscopy (NIRS) is a non-invasive technique that estimates regional cerebral oxygen saturation ( $$\hbox {rSO}_2$$ ) by analyzing near-infrared light transmitted through biological tissue. Despite its portability and cost-effectiveness, commercial NIRS systems that employ spatially resolved spectroscopy (SRS) algorithms lack sufficient reliability to distinguish between normal and stroke-affected conditions because of oversimplified assumptions. In this study, we propose an artificial intelligence–assisted NIRS system that analyzes high-density optical measurements to estimate cerebral oxygenation beyond the simplified assumptions of conventional SRS algorithms. Trained on an MRI-based synthetic dataset using cortical $$\hbox {rSO}_2$$ as the target label, the proposed model leverages measurements obtained at multiple source–detector distances to exploit depth-dependent spatial information and improve sensitivity to cortical oxygenation signals. The proposed system was validated through a porcine common carotid artery occlusion experiment and compared with a conventional SRS-based NIRS system. Both systems showed decreases during occlusion and recovery after reperfusion, but statistically significant baseline-relative changes after multiple-comparison correction were observed only for NIRSIT-X. Furthermore, we compared the measured oxygen saturation against jugular venous oxygen saturation ( $$\hbox {SjvO}_2$$ ) as a physiological reference. In conclusion, based on linear mixed-effects modeling, the proposed system demonstrated a substantially stronger association with $$\hbox {SjvO}_2$$ than the conventional system, achieving a markedly higher marginal $$R^2$$ (0.561 vs. 0.177), indicating stronger physiological relevance for cerebral oxygenation monitoring.

Authors

Publication Details

Journal
Scientific Reports
Published
2026-09-10
DOI
https://doi.org/10.1038/s41598-026-70638-8
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-assisted high-density near-infrared spectroscopy system for cerebral oxygen saturation measurement in a porcine ischemia model

Woon Yong Kwon, Sang‐Bae Ko, Seongkwon Yu, Heesu Park et al.
Scientific Reports
Optical Imaging and Spectroscopy Techniques
article

AI-assisted high-density near-infrared spectroscopy system for cerebral oxygen saturation measurement in a porcine ischemia model

Woon Yong Kwon, Sang‐Bae Ko, Seongkwon Yu, Heesu Park, Bumjun Koh, Jimin Lee, Tae Jung Kim, Hayoung Kim, Hyeon-Min Bae, Jae-Myoung Kim
article en

Abstract

Abstract Stroke is one of the leading causes of mortality and is characterized by a sudden interruption of cerebral perfusion, resulting in neurological impairment. Especially in large-vessel occlusion (LVO), the absence of timely reperfusion therapy can lead to severe ischemic injury, causing permanent disability or death. Near-infrared spectroscopy (NIRS) is a non-invasive technique that estimates regional cerebral oxygen saturation ( $$\hbox {rSO}_2$$ ) by analyzing near-infrared light transmitted through biological tissue. Despite its portability and cost-effectiveness, commercial NIRS systems that employ spatially resolved spectroscopy (SRS) algorithms lack sufficient reliability to distinguish between normal and stroke-affected conditions because of oversimplified assumptions. In this study, we propose an artificial intelligence–assisted NIRS system that analyzes high-density optical measurements to estimate cerebral oxygenation beyond the simplified assumptions of conventional SRS algorithms. Trained on an MRI-based synthetic dataset using cortical $$\hbox {rSO}_2$$ as the target label, the proposed model leverages measurements obtained at multiple source–detector distances to exploit depth-dependent spatial information and improve sensitivity to cortical oxygenation signals. The proposed system was validated through a porcine common carotid artery occlusion experiment and compared with a conventional SRS-based NIRS system. Both systems showed decreases during occlusion and recovery after reperfusion, but statistically significant baseline-relative changes after multiple-comparison correction were observed only for NIRSIT-X. Furthermore, we compared the measured oxygen saturation against jugular venous oxygen saturation ( $$\hbox {SjvO}_2$$ ) as a physiological reference. In conclusion, based on linear mixed-effects modeling, the proposed system demonstrated a substantially stronger association with $$\hbox {SjvO}_2$$ than the conventional system, achieving a markedly higher marginal $$R^2$$ (0.561 vs. 0.177), indicating stronger physiological relevance for cerebral oxygenation monitoring.

Scientific Reports
Good health and well-being
Openalex Percentile: Top 11%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.