Assessment of emphysema with simulated low-dose dark-field radiography

Abstract Objective Dark-field radiography allows the visualization of lung tissue changes associated with pulmonary emphysema. Simulations were used to investigate the impact of radiation dose reduction on the diagnostic accuracy of emphysema detection. Materials and methods Dark-field and attenuation chest radiographs acquired during an ongoing clinical study were used to simulate multiple low-dose counterparts corresponding to median effective doses between 7 and 18 µSv. All study participants had undergone a medically indicated chest computed tomography scan that showed either pulmonary emphysema or no lung pathologies. In a randomized reader study, three radiologists independently assessed the simulated low-dose dark-field and attenuation radiographs as well as the original images for the presence of emphysema. The area under the curves (AUC) of the receiver operating characteristics (ROC) were analyzed using Obuchowski’s method. ROC curves were also generated by using different values of the dark-field coefficient to differentiate between absent and at least mild emphysema. Results The original (full-dose) images and simulated low-dose images of 93 participants (57 males, 36 females) were included, with participants’ median age of 66 years (interquartile range 54 to 73 years). The radiologists’ ROC curves of the simulated low-dose images at 11 µSv (AUC = 0.84) did not differ significantly ( p = 0.177) from the full-dose curve (AUC = 0.86). For all dose levels, the dark-field coefficient could distinguish between absent and at least mild emphysema with an AUC of 0.85. Conclusion Radiation dose reduction in dark-field imaging for emphysema assessment might be feasible, with median effective doses potentially as low as 11 µSv. Key Points Question How does radiation dose reduction affect the diagnostic potential of dark-field chest radiographs? Findings For actual, regular-dose (36 µSv) dark-field radiographs, AUC was 0.86, and 0.84 for simulated low-dose images. Down to 7 µSv, the dark-field coefficient AUC was 0.85. Relevance statement Simulations suggest that the radiation dose in dark-field chest imaging could be lowered to 11 µSv, indicating the technique’s potential for ultra-low-dose imaging, which could be especially beneficial for potential clinical screening applications in the future.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2026-09-10
DOI
https://doi.org/10.1186/s41747-026-00796-x
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of emphysema with simulated low-dose dark-field radiography

Henriette Bast, Franz Pfeiffer, Daniela Pfeiffer, Rafael Schick et al.
European Radiology Experimental
Advanced X-ray Imaging Techniques
article

Assessment of emphysema with simulated low-dose dark-field radiography

Henriette Bast, Franz Pfeiffer, Daniela Pfeiffer, Rafael Schick, Marcus R. Makowski, A P Sauter, Bernhard Renger, Florian T. Gassert, Alexander W. Marka, Thomas Koehler, Gregor Zimmermann
article en

Abstract

Abstract Objective Dark-field radiography allows the visualization of lung tissue changes associated with pulmonary emphysema. Simulations were used to investigate the impact of radiation dose reduction on the diagnostic accuracy of emphysema detection. Materials and methods Dark-field and attenuation chest radiographs acquired during an ongoing clinical study were used to simulate multiple low-dose counterparts corresponding to median effective doses between 7 and 18 µSv. All study participants had undergone a medically indicated chest computed tomography scan that showed either pulmonary emphysema or no lung pathologies. In a randomized reader study, three radiologists independently assessed the simulated low-dose dark-field and attenuation radiographs as well as the original images for the presence of emphysema. The area under the curves (AUC) of the receiver operating characteristics (ROC) were analyzed using Obuchowski’s method. ROC curves were also generated by using different values of the dark-field coefficient to differentiate between absent and at least mild emphysema. Results The original (full-dose) images and simulated low-dose images of 93 participants (57 males, 36 females) were included, with participants’ median age of 66 years (interquartile range 54 to 73 years). The radiologists’ ROC curves of the simulated low-dose images at 11 µSv (AUC = 0.84) did not differ significantly ( p = 0.177) from the full-dose curve (AUC = 0.86). For all dose levels, the dark-field coefficient could distinguish between absent and at least mild emphysema with an AUC of 0.85. Conclusion Radiation dose reduction in dark-field imaging for emphysema assessment might be feasible, with median effective doses potentially as low as 11 µSv. Key Points Question How does radiation dose reduction affect the diagnostic potential of dark-field chest radiographs? Findings For actual, regular-dose (36 µSv) dark-field radiographs, AUC was 0.86, and 0.84 for simulated low-dose images. Down to 7 µSv, the dark-field coefficient AUC was 0.85. Relevance statement Simulations suggest that the radiation dose in dark-field chest imaging could be lowered to 11 µSv, indicating the technique’s potential for ultra-low-dose imaging, which could be especially beneficial for potential clinical screening applications in the future.

European Radiology ExperimentalVol. 10(1)
TUM Klinikum (DE), Philips (Germany) (DE), Technical University of Munich (DE)
Good health and well-being
Openalex Percentile: Top 12%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.