Automated B-lines quantification with lung ultrasound in mechanically ventilated patients

BACKGROUND: If ultrasound dedicated software for the identification and quantification of interstitial syndrome is equal or superior to experts observation is still being explored. The primary objective of this study was to compare the performance of an automatic method based on a dedicated software algorithm with that of expert clinicians in terms of B-lines quantification. METHODS: Adult patients with acute respiratory failure who were deeply sedated, paralysed and mechanically ventilated were prospectively enrolled within 48 hours from ICU admission and underwent lung ultrasound by a trained physician. For each patient, 12 clips were stored, one for each thoracic region. The clips were then analyzed automatically using a built-in automatic recognition system and visually by two experts. A score of 0 was assigned if fewer than two B-lines were detected, a score of 1 if three or more B-lines were detected and a score of 2 if coalescent B-lines were detected. RESULTS: A total of 40 patients were included in the study. Out of the 480 clips analysed, 54.2% had a lung score of 0, 6.8% had a lung score of 1, 8.8% had a lung score of 2 and 20.2% had a lung score of 3. The agreement between the experts in detecting the scores 0, 1, 2 was excellent (ICC = 0.82) in 383 (79.8%) clips. The agreement between the automatic system and the experts was poor (ICC = 0.33), with a significant difference (p < 0.001). CONCLUSIONS: In mechanically ventilated patients with acute respiratory failure, an automatic B-lines quantification system did not present an acceptable accuracy compared to expert consensus for B-lines counting, probably due to the coexistence of consolidation and pleural effusion.

Authors

Institutions

Publication Details

Journal
Multidisciplinary Respiratory Medicine
Published
2026-09-10
DOI
https://doi.org/10.5826/mrm.2026.1069
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Automated B-lines quantification with lung ultrasound in mechanically ventilated patients

Arianna Ciabattoni, Tommaso Pozzi, Dejan Radovanovic, Davide Chiumello et al.
Multidisciplinary Respiratory Medicine
Ultrasound in Clinical Applications
article

Automated B-lines quantification with lung ultrasound in mechanically ventilated patients

Arianna Ciabattoni, Tommaso Pozzi, Dejan Radovanovic, Davide Chiumello, Silvia Coppola, Martina Gurgitano, Alessandro Monte, Gianpaolo Carrafiello
article en

Abstract

BACKGROUND: If ultrasound dedicated software for the identification and quantification of interstitial syndrome is equal or superior to experts observation is still being explored. The primary objective of this study was to compare the performance of an automatic method based on a dedicated software algorithm with that of expert clinicians in terms of B-lines quantification. METHODS: Adult patients with acute respiratory failure who were deeply sedated, paralysed and mechanically ventilated were prospectively enrolled within 48 hours from ICU admission and underwent lung ultrasound by a trained physician. For each patient, 12 clips were stored, one for each thoracic region. The clips were then analyzed automatically using a built-in automatic recognition system and visually by two experts. A score of 0 was assigned if fewer than two B-lines were detected, a score of 1 if three or more B-lines were detected and a score of 2 if coalescent B-lines were detected. RESULTS: A total of 40 patients were included in the study. Out of the 480 clips analysed, 54.2% had a lung score of 0, 6.8% had a lung score of 1, 8.8% had a lung score of 2 and 20.2% had a lung score of 3. The agreement between the experts in detecting the scores 0, 1, 2 was excellent (ICC = 0.82) in 383 (79.8%) clips. The agreement between the automatic system and the experts was poor (ICC = 0.33), with a significant difference (p < 0.001). CONCLUSIONS: In mechanically ventilated patients with acute respiratory failure, an automatic B-lines quantification system did not present an acceptable accuracy compared to expert consensus for B-lines counting, probably due to the coexistence of consolidation and pleural effusion.

Multidisciplinary Respiratory MedicineVol. 21(Vol. 21 (2026))
University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Ospedale San Paolo (IT), ASST Fatebenefratelli Sacco (IT), Azienda Socio Sanitaria Territoriale Santi Paolo e Carlo
No poverty
Openalex Percentile: Top 10%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.