CARE-X: Capability-Aware Reliable and Explainable AI for Healthcare Operations

Healthcare artificial intelligence increasingly functions as part of an augmented system in which information, computational resources, external interfaces, and operating rules can alter what a fixed predictive component is able to accomplish. Yet evaluation commonly focuses on final performance, leaving these dependencies largely unexamined. We introduce CARE-X, a non-diagnostic framework for auditing capability in assistive healthcare workflows across the complete 2^4 factorial lattice of resources, information, actions/interfaces, and rules. CARE-X combines exact Boolean-lattice attribution with minimal enabling sets, minimal failure cuts, survival and concentration measures, and workflow-level Capability Passports. We show formally that two augmented systems can exhibit identical technical completion under every intervention while differing in safe capability. Controlled experiments include a 2,048-case simulator and a frozen Random Forest trained on 14,000 synthetic cases. We further examine CARE-X using the open MIMIC-IV-ED Demo, comprising 222 emergency-department stays from 64 patients and 666 non-diagnostic workflow cases. Full augmentation achieves a safe-handling rate of 0.9384. Removing either information or actions/interfaces reduces this rate by 0.6051, with the tied dependency pattern reproduced in a patient-disjoint split. Exact Möbius reconstruction error is zero. In contrast, removal of the rules channel produces a loss of only 0.0015, showing that dependencies observed under controlled conditions need not transfer uniformly to real records. CARE-X thus provides a way to distinguish predictive competence from the operational dependencies that enable safe system capability, while treating the real-record analysis as feasibility evidence rather than clinical validation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-09-09
DOI
https://doi.org/10.5281/zenodo.22676687
Primary Topic
Healthcare Technology and Patient Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
preprint

CARE-X: Capability-Aware Reliable and Explainable AI for Healthcare Operations

Arvind Hans, Md. Amir Khusru Akhtar
Zenodo (CERN European Organization for Nuclear Research)
Healthcare Technology and Patient Monitoring
preprint

CARE-X: Capability-Aware Reliable and Explainable AI for Healthcare Operations

Arvind Hans, Md. Amir Khusru Akhtar
preprint en

Abstract

Healthcare artificial intelligence increasingly functions as part of an augmented system in which information, computational resources, external interfaces, and operating rules can alter what a fixed predictive component is able to accomplish. Yet evaluation commonly focuses on final performance, leaving these dependencies largely unexamined. We introduce CARE-X, a non-diagnostic framework for auditing capability in assistive healthcare workflows across the complete 2^4 factorial lattice of resources, information, actions/interfaces, and rules. CARE-X combines exact Boolean-lattice attribution with minimal enabling sets, minimal failure cuts, survival and concentration measures, and workflow-level Capability Passports. We show formally that two augmented systems can exhibit identical technical completion under every intervention while differing in safe capability. Controlled experiments include a 2,048-case simulator and a frozen Random Forest trained on 14,000 synthetic cases. We further examine CARE-X using the open MIMIC-IV-ED Demo, comprising 222 emergency-department stays from 64 patients and 666 non-diagnostic workflow cases. Full augmentation achieves a safe-handling rate of 0.9384. Removing either information or actions/interfaces reduces this rate by 0.6051, with the tied dependency pattern reproduced in a patient-disjoint split. Exact Möbius reconstruction error is zero. In contrast, removal of the rules channel produces a loss of only 0.0015, showing that dependencies observed under controlled conditions need not transfer uniformly to real records. CARE-X thus provides a way to distinguish predictive competence from the operational dependencies that enable safe system capability, while treating the real-record analysis as feasibility evidence rather than clinical validation.

Zenodo (CERN European Organization for Nuclear Research)
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.