Feasibility Evaluation of a Novel Bilateral Hand and Finger Training Device in Patients with Hand Dysfunction: A Preliminary Study

Background/Objectives: The Synchronized Hand Interface for Neurorehabilitation and Innovation (SHINI) is a mechanical device that uses voluntary movement of the unaffected or less affected upper limb to generate synchronized bilateral hand and finger movements without biological signal detection or electronic control. This exploratory study evaluated SHINI’s technical operability and practical limitations during a single supervised session. Methods: Seven participants with hand dysfunction of varied etiologies attempted one 10 min session. Completion status was categorized as completed without therapist intervention, completed with therapist intervention, or not completed; no quantitative acceptability threshold was prespecified. Secondary outcomes were adverse events, overall perceived exertion and upper-limb fatigue assessed using the modified Borg Scale, exploratory pre- and post-session modified Ashworth Scale scores, and participant and therapist feedback. Results: Three participants (42.9%) completed the session without therapist intervention, three (42.9%) completed it with therapist intervention, and one (14.3%) did not complete it. Hand or forearm displacement affected four participants (57.1%), including the participant who discontinued. No adverse events occurred. Perceived exertion and upper-limb fatigue were generally low, no consistent direction of change in modified Ashworth Scale scores was observed, and feedback emphasized the need for improved fixation and adjustability. Conclusions: SHINI showed preliminary technical operability during a single supervised session, but the findings do not establish feasibility for independent or semi-supervised use. With improved fixation and adaptability, SHINI may offer a simple mechanical approach to repetitive bilateral hand training. Repeated-use studies are required to evaluate usability, safety, and clinical effectiveness.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2026-09-09
DOI
https://doi.org/10.3390/healthcare14182915
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility Evaluation of a Novel Bilateral Hand and Finger Training Device in Patients with Hand Dysfunction: A Preliminary Study

Yasushi Hada, Kei Takehara, Shigeki Kubota, Yuki Mataki et al.
Healthcare
Stroke Rehabilitation and Recovery
article

Feasibility Evaluation of a Novel Bilateral Hand and Finger Training Device in Patients with Hand Dysfunction: A Preliminary Study

Yasushi Hada, Kei Takehara, Shigeki Kubota, Yuki Mataki, Yukiyo Shimizu, Gaku Watanabe
article en

Abstract

Background/Objectives: The Synchronized Hand Interface for Neurorehabilitation and Innovation (SHINI) is a mechanical device that uses voluntary movement of the unaffected or less affected upper limb to generate synchronized bilateral hand and finger movements without biological signal detection or electronic control. This exploratory study evaluated SHINI’s technical operability and practical limitations during a single supervised session. Methods: Seven participants with hand dysfunction of varied etiologies attempted one 10 min session. Completion status was categorized as completed without therapist intervention, completed with therapist intervention, or not completed; no quantitative acceptability threshold was prespecified. Secondary outcomes were adverse events, overall perceived exertion and upper-limb fatigue assessed using the modified Borg Scale, exploratory pre- and post-session modified Ashworth Scale scores, and participant and therapist feedback. Results: Three participants (42.9%) completed the session without therapist intervention, three (42.9%) completed it with therapist intervention, and one (14.3%) did not complete it. Hand or forearm displacement affected four participants (57.1%), including the participant who discontinued. No adverse events occurred. Perceived exertion and upper-limb fatigue were generally low, no consistent direction of change in modified Ashworth Scale scores was observed, and feedback emphasized the need for improved fixation and adjustability. Conclusions: SHINI showed preliminary technical operability during a single supervised session, but the findings do not establish feasibility for independent or semi-supervised use. With improved fixation and adaptability, SHINI may offer a simple mechanical approach to repetitive bilateral hand training. Repeated-use studies are required to evaluate usability, safety, and clinical effectiveness.

HealthcareVol. 14(18)
Ibaraki Prefectural University of Health Sciences (JP), University of Tsukuba (JP), University of Tsukuba Hospital (JP)
Industry, innovation and infrastructure
Openalex Percentile: Top 14%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.