Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration

The AWAKE experiment at CERN uses high-energy proton bunches to drive plasma wakefields capable of accelerating electron bunches up to hundreds of GeV in a single plasma. Realising this potential requires a plasma source that can extend to tens of metres while maintaining high longitudinal uniformity and reproducibility. Towards this goal, we report on the first experimental characterisation and beam-based validation of a 10-metre-long pulsed-DC discharge plasma source (DPS) used as an alternative to the laser-ionised rubidium vapour plasma source (VPS). The DPS reliably delivered plasma densities in three noble gases (He, Ar, Xe) at electron densities between 10 14 and 10 15 cm − 3 . Proton bunch self-modulation was observed with all three gases, and the resulting modulation frequency was used as a beam-based diagnostic of the plasma density, showing good agreement with laboratory interferometry measurements. The event-to-event modulation frequency was demonstrated to be reproducible to within 0.63%, comparable to that of the VPS, within the resolution of the present diagnostic. These results establish the DPS as a valid alternative plasma source for beam-driven wakefield experiments, and support its further development towards longer plasma lengths. The present design is tailored to AWAKE requirements, but the underlying discharge concept provides a route to long, reproducible plasma sources with straightforward density control through discharge-beam timing for other beam-plasma experiments.

Authors

Publication Details

Journal
Physical Review Research
Published
2026-11-19
DOI
https://doi.org/10.1103/33h4-lf1m
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration

Eleonora Belli, P. Muggli, L. Verra, T. Lefèvre et al.
2 links
Physical Review Research
Laser-Plasma Interactions and Diagnostics
article

Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration

Eleonora Belli, P. Muggli, L. Verra, T. Lefèvre, P.N. Burrows, F. Silva, J. Pisani, M. Moreira, C. Davut, Eduardo Granados, N. Lopes, N. Torrado, A. Dexter, E. Gschwendtner, S. Doebert, Daniel Harryman, Konstantin V. Lotov, A. Sublet, M. Turner, A. Gerbershagen, C. Amoedo, A. Clairembaud, J. Mezger, N. Z. van Gils, F. Pannell, M. Bergamaschi, V. Yarygova, D. Easton, P. Tuev, N. Okhotnikov, J. Uncles, G. Zevi Della Porta, G. Tenasini, R. Apsimon, M. Krupa, J. McGunigal, A. Eager, C. Stollberg, R. Rossel, Y. Alekajbaf, C. Swain, M. Chung, S. Burger, C. Pakuza, W. Zhang, O. Grulke, B. Woolley, E. Guran, M. Hibberd, P. Karataev, D. A. Cooke, J. Vieira, A. Boccardi, H. Jaworska, C. C. Ahdida, T. Bogey, L. Stant, A. Pardons, F. Sharmin, M. Wing, B. Spear, J. Farmer, C. Welsch, T. Bachmann, O. Apsimon, R. Fonseca, S. Norman, A. Omoumi, I. Furno, M. Baquero, D. Ghosal, F. Velotti, H. Saberi, D. Dancila, L. Silva, T. Wilson, A. Topaloudis, C. Badiali, F. Kraus, M. A. Kedves, B. Moser, Z. Najmudin, A. Pukhov, J. Wolfenden, M. V. Santos, G. Demeter, B. Elward, L. Ranc, O. Schmitz, J. Gregory, R. Karimov, B. Buttenschön, G. Xia, A. Caldwell, C. C. Cobo
article en

Abstract

The AWAKE experiment at CERN uses high-energy proton bunches to drive plasma wakefields capable of accelerating electron bunches up to hundreds of GeV in a single plasma. Realising this potential requires a plasma source that can extend to tens of metres while maintaining high longitudinal uniformity and reproducibility. Towards this goal, we report on the first experimental characterisation and beam-based validation of a 10-metre-long pulsed-DC discharge plasma source (DPS) used as an alternative to the laser-ionised rubidium vapour plasma source (VPS). The DPS reliably delivered plasma densities in three noble gases (He, Ar, Xe) at electron densities between 10 14 and 10 15 cm − 3 . Proton bunch self-modulation was observed with all three gases, and the resulting modulation frequency was used as a beam-based diagnostic of the plasma density, showing good agreement with laboratory interferometry measurements. The event-to-event modulation frequency was demonstrated to be reproducible to within 0.63%, comparable to that of the VPS, within the resolution of the present diagnostic. These results establish the DPS as a valid alternative plasma source for beam-driven wakefield experiments, and support its further development towards longer plasma lengths. The present design is tailored to AWAKE requirements, but the underlying discharge concept provides a route to long, reproducible plasma sources with straightforward density control through discharge-beam timing for other beam-plasma experiments.

Physical Review Research
National Science Foundation, Cockcroft Institute, CERN, National Research Foundation of Korea, Science and Technology Facilities Council, Deutsches Elektronen-Synchrotron
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon