Intraoperative patellofemoral load varies between total knee replacement and patellofemoral joint resurfacing, and across TKR implant systems

Abstract Introduction Patellofemoral joint loading is influenced by implant design and surgical execution during knee replacement. Altered patellofemoral mechanics have been implicated in postoperative symptoms, yet the magnitude and variability of intraoperative load changes across different replacement procedures and implant systems remain incompletely characterised. The aim of this registry study was to describe and quantify intraoperative patellofemoral joint load changes following total knee replacement (TKR) and patellofemoral joint resurfacing (PFJR), focusing on cumulative and compartment-specific load redistribution. Materials and methods This observational registry study analysed prospectively collected intraoperative patellofemoral joint load measurements from 291 knee replacement procedures. Load was recorded in medial, lateral, superior, and inferior compartments before and after trial component implantation. Absolute and percentage changes in compartmental and cumulative load were calculated. Descriptive analyses examined the distribution and variability of load change across procedure type and implant system, with implant comparisons restricted to TKR procedures. No formal hypothesis testing was pre-specified, and no adjustment for potential confounding variables was undertaken. Results Cumulative patellofemoral load change demonstrated substantial inter-individual variability. While most cases clustered around small percentage changes, a distinct subset of patients exhibited large cumulative load increases exceeding + 70%. TKR procedures demonstrated a broader distribution and higher observed frequency of large cumulative load increases compared with PFJR. Implant-specific analysis of TKR procedures revealed descriptive differences in cumulative load distributions between implant cohorts, with certain implant systems showing a higher observed frequency of large load increases within this dataset. Compartmental magnitude analysis demonstrated that lateral and superior compartments accounted for most of the load redistribution, whereas medial and inferior compartments contributed minimally. Conclusions Intraoperative patellofemoral load redistribution following knee replacement is highly variable and was observed to differ descriptively between procedure types and implant systems. Load changes were predominantly observed in the lateral and superior compartments, with a meaningful subset of patients experiencing large cumulative increases. Registry-based intraoperative load measurement allows detailed characterisation of patellofemoral biomechanics beyond cumulative metrics alone and may inform future investigations into implant design and surgical optimisation. Given the observational registry design and absence of confounder adjustment, these findings should be interpreted as descriptive associations rather than causal relationships.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-09-09
DOI
https://doi.org/10.1007/s00402-026-06500-3
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative patellofemoral load varies between total knee replacement and patellofemoral joint resurfacing, and across TKR implant systems

John Naybour, David Barrett, Nick London, Annabel Watson et al.
Archives of Orthopaedic and Trauma Surgery
Total Knee Arthroplasty Outcomes
article

Intraoperative patellofemoral load varies between total knee replacement and patellofemoral joint resurfacing, and across TKR implant systems

John Naybour, David Barrett, Nick London, Annabel Watson, Louis Phillipson
article en

Abstract

Abstract Introduction Patellofemoral joint loading is influenced by implant design and surgical execution during knee replacement. Altered patellofemoral mechanics have been implicated in postoperative symptoms, yet the magnitude and variability of intraoperative load changes across different replacement procedures and implant systems remain incompletely characterised. The aim of this registry study was to describe and quantify intraoperative patellofemoral joint load changes following total knee replacement (TKR) and patellofemoral joint resurfacing (PFJR), focusing on cumulative and compartment-specific load redistribution. Materials and methods This observational registry study analysed prospectively collected intraoperative patellofemoral joint load measurements from 291 knee replacement procedures. Load was recorded in medial, lateral, superior, and inferior compartments before and after trial component implantation. Absolute and percentage changes in compartmental and cumulative load were calculated. Descriptive analyses examined the distribution and variability of load change across procedure type and implant system, with implant comparisons restricted to TKR procedures. No formal hypothesis testing was pre-specified, and no adjustment for potential confounding variables was undertaken. Results Cumulative patellofemoral load change demonstrated substantial inter-individual variability. While most cases clustered around small percentage changes, a distinct subset of patients exhibited large cumulative load increases exceeding + 70%. TKR procedures demonstrated a broader distribution and higher observed frequency of large cumulative load increases compared with PFJR. Implant-specific analysis of TKR procedures revealed descriptive differences in cumulative load distributions between implant cohorts, with certain implant systems showing a higher observed frequency of large load increases within this dataset. Compartmental magnitude analysis demonstrated that lateral and superior compartments accounted for most of the load redistribution, whereas medial and inferior compartments contributed minimally. Conclusions Intraoperative patellofemoral load redistribution following knee replacement is highly variable and was observed to differ descriptively between procedure types and implant systems. Load changes were predominantly observed in the lateral and superior compartments, with a meaningful subset of patients experiencing large cumulative increases. Registry-based intraoperative load measurement allows detailed characterisation of patellofemoral biomechanics beyond cumulative metrics alone and may inform future investigations into implant design and surgical optimisation. Given the observational registry design and absence of confounder adjustment, these findings should be interpreted as descriptive associations rather than causal relationships.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
UK Health Forum (GB), University of Southampton (GB), Leeds Beckett University (GB)
Openalex Percentile: Top 8%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.