Implant migration and clinical outcomes with cemented vs cementless Motec cups in total trapeziometacarpal arthroplasty: a 10-year prospective RSA cohort study of 69 patients

BACKGROUND AND PURPOSE: Few clinical studies have assessed migration of trapeziometacarpal implants, and long-term outcomes are warranted. We aimed to evaluate 10-year migration, clinical outcomes, and revisions of cementless and cemented Motec cups. Additionally, early migration of revised and non-revised cups, and the association between clinical outcomes and cup revision were investigated. METHODS: Radiostereometric analysis (RSA) was performed after cast removal (baseline = 3 weeks), at 3 months, 1, 2, 5, and 10 years. Clinical outcomes and revisions were evaluated prospectively. RESULTS: 22 cementless Motec titanium-screw cups were inserted from 2009 to 2010, followed by 47 cemented Motec all-polyethylene cups inserted with Palacos bone cement from 2011 to 2012. At the 10-year follow-up, mean cup total translation (TT) was 0.79 mm (standard error [SE] 0.55) for cementless cups (n = 3) and 1.33 mm (SE 0.30) for cemented cups (n = 10), with cemented cups demonstrating 0.54 mm (CI -0.68 to 1.77) higher translation. 10 of 22 cementless cups and 15 of 47 cemented cups were revised, primarily due to aseptic loosening. There was a difference in TT between revised and non-revised cups of 1.75 mm (CI 0.45-3.05) for cementless cups at 1-year follow-up, and of 1.11 mm (CI 0.30-1.93) for cemented cups at 2-year follow-up. Increased pain in activity and Disabilities of the Arm, Shoulder, and Hand (QDASH) score was associated with revision. At 10 years, patients with retained cups reported high satisfaction and grip strength, pain, and QDASH improvement above the minimal clinically important difference compared with preoperatively. CONCLUSION: 10-year cup migration was similar between Motec cup groups. Revised cups migrated more than non-revised cups in both groups, and pain in activity and QDASH score were associated with revision. As such, decline in clinical outcomes, as well as progression in cup TT, seem to be useful predictors of cup revision.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica
Published
2026-09-09
DOI
https://doi.org/10.2340/17453674.2026.46544
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Implant migration and clinical outcomes with cemented vs cementless Motec cups in total trapeziometacarpal arthroplasty: a 10-year prospective RSA cohort study of 69 patients

Torben Bæk Hansen, Maiken Stilling, Janni Kjærgaard Thillemann, Emil Rautio
Acta Orthopaedica
Orthopedic Surgery and Rehabilitation
article

Implant migration and clinical outcomes with cemented vs cementless Motec cups in total trapeziometacarpal arthroplasty: a 10-year prospective RSA cohort study of 69 patients

Torben Bæk Hansen, Maiken Stilling, Janni Kjærgaard Thillemann, Emil Rautio
article en

Abstract

BACKGROUND AND PURPOSE: Few clinical studies have assessed migration of trapeziometacarpal implants, and long-term outcomes are warranted. We aimed to evaluate 10-year migration, clinical outcomes, and revisions of cementless and cemented Motec cups. Additionally, early migration of revised and non-revised cups, and the association between clinical outcomes and cup revision were investigated. METHODS: Radiostereometric analysis (RSA) was performed after cast removal (baseline = 3 weeks), at 3 months, 1, 2, 5, and 10 years. Clinical outcomes and revisions were evaluated prospectively. RESULTS: 22 cementless Motec titanium-screw cups were inserted from 2009 to 2010, followed by 47 cemented Motec all-polyethylene cups inserted with Palacos bone cement from 2011 to 2012. At the 10-year follow-up, mean cup total translation (TT) was 0.79 mm (standard error [SE] 0.55) for cementless cups (n = 3) and 1.33 mm (SE 0.30) for cemented cups (n = 10), with cemented cups demonstrating 0.54 mm (CI -0.68 to 1.77) higher translation. 10 of 22 cementless cups and 15 of 47 cemented cups were revised, primarily due to aseptic loosening. There was a difference in TT between revised and non-revised cups of 1.75 mm (CI 0.45-3.05) for cementless cups at 1-year follow-up, and of 1.11 mm (CI 0.30-1.93) for cemented cups at 2-year follow-up. Increased pain in activity and Disabilities of the Arm, Shoulder, and Hand (QDASH) score was associated with revision. At 10 years, patients with retained cups reported high satisfaction and grip strength, pain, and QDASH improvement above the minimal clinically important difference compared with preoperatively. CONCLUSION: 10-year cup migration was similar between Motec cup groups. Revised cups migrated more than non-revised cups in both groups, and pain in activity and QDASH score were associated with revision. As such, decline in clinical outcomes, as well as progression in cup TT, seem to be useful predictors of cup revision.

Acta OrthopaedicaVol. 97
Aarhus University Hospital (DK)
Reduced inequalities
Openalex Percentile: Top 8%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.