AI-Enhanced Directional Pedestrian Sensing Using a Single MEMS Accelerometer

Artificial intelligence can extend the functional capabilities of embedded sensors by extracting application-level information from physical measurements. This study investigates whether footstep-induced floor vibrations acquired with a single triaxial MEMS accelerometer contain sufficient information to characterize pedestrian path orientation and travel sense. A custom sensing platform based on an ADXL355 accelerometer and an ESP32 microcontroller was developed to acquire the structural vibration response at 4 kSPS. Lightweight temporal features were processed using a Random Forest classifier. The primary assessment used leakage-aware event-level cross-validation, with complete footsteps as the data-partitioning units. Under this more conservative protocol, discrimination of the complete A–K movement-label set was poor, whereas a compact 12-dimensional descriptor representation achieved 73.18% accuracy, 71.52% balanced accuracy, and 70.98% macro-F1 for X/Y path-orientation classification. Reliable positive/negative travel-sense discrimination could not be demonstrated from isolated footsteps. For historical comparison, the original sample-level procedure yielded 97.09% accuracy, but this value is retained only as a within-sequence reference because densely sampled observations contain strongly overlapping information. The findings provide proof-of-concept evidence that a single floor-mounted MEMS accelerometer can capture coarse pedestrian path-orientation information without cameras or spatially distributed vibration-sensor networks. Feature extraction and classifier inference were performed offline; broader validation across participants, sessions, floor structures, and realistic disturbances is required before deployment as an embedded edge AI sensing node.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-09-09
DOI
https://doi.org/10.3390/s26185736
Primary Topic
Gait Recognition and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

AI-Enhanced Directional Pedestrian Sensing Using a Single MEMS Accelerometer

Carles Pous, Llorenç Burgas, Pere Martí-Puig, Joaquim Massana et al.
Sensors
Gait Recognition and Analysis
article

AI-Enhanced Directional Pedestrian Sensing Using a Single MEMS Accelerometer

Carles Pous, Llorenç Burgas, Pere Martí-Puig, Joaquim Massana, Narcís Planellas, Enric Casademont Ferrés
article en

Abstract

Artificial intelligence can extend the functional capabilities of embedded sensors by extracting application-level information from physical measurements. This study investigates whether footstep-induced floor vibrations acquired with a single triaxial MEMS accelerometer contain sufficient information to characterize pedestrian path orientation and travel sense. A custom sensing platform based on an ADXL355 accelerometer and an ESP32 microcontroller was developed to acquire the structural vibration response at 4 kSPS. Lightweight temporal features were processed using a Random Forest classifier. The primary assessment used leakage-aware event-level cross-validation, with complete footsteps as the data-partitioning units. Under this more conservative protocol, discrimination of the complete A–K movement-label set was poor, whereas a compact 12-dimensional descriptor representation achieved 73.18% accuracy, 71.52% balanced accuracy, and 70.98% macro-F1 for X/Y path-orientation classification. Reliable positive/negative travel-sense discrimination could not be demonstrated from isolated footsteps. For historical comparison, the original sample-level procedure yielded 97.09% accuracy, but this value is retained only as a within-sequence reference because densely sampled observations contain strongly overlapping information. The findings provide proof-of-concept evidence that a single floor-mounted MEMS accelerometer can capture coarse pedestrian path-orientation information without cameras or spatially distributed vibration-sensor networks. Feature extraction and classifier inference were performed offline; broader validation across participants, sessions, floor structures, and realistic disturbances is required before deployment as an embedded edge AI sensing node.

SensorsVol. 26(18)
Universitat de Vic - Universitat Central de Catalunya (ES), Universitat de Girona (ES)
Reduced inequalities, Peace, Justice and strong institutions
Openalex Percentile: Top 20%
Gait Recognition and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.