Combining Small Aperture Approach and Toric Correction for Irregular Astigmatism Management

Purpose: Irregular astigmatism poses a challenge in cataract surgery due to its complex geometry and associated higher-order aberrations (HOAs), which limit the efficacy of conventional toric intraocular lenses (IOLs). IOLs featuring a small-aperture have shown promise in managing such cases through the “pinhole effect,” yet they do not correct the underlying astigmatic power. This study investigates the potential of a hybrid IOL design featuring both small-aperture and toric elements to address these limitations. Setting: David J. Apple Laboratory for Ocular Pathology. Design: Experimental study. Methods: A retrospective analysis of 22 eyes with irregular astigmatism was conducted using semi-personalized eye models derived from Pentacam (Oculus) tomography data. Simulations were performed in OpticStudio to evaluate three IOL systems: a toric IOL, a small-aperture, and a combined small-aperture+toric IOL. Image quality was assessed using Strehl Ratio (SR) and RMS error. Landolt C simulations and correlation analyses were also performed. Results: The hybrid IOL significantly outperformed the toric and small-aperture IOLs alone, achieving mean SR of 0.80±0.17 (vs. 0.10±0.07 and 0.20±0.19, respectively, p<0.001 ) and the lowest RMS error (0.07 µm, p<0.001 ). Simulations demonstrated superior visual quality and less sensitivity to corneal asymmetry. R 2 analyses confirmed a strong association between corneal astigmatism and improved optical quality in the combined model. Conclusions: Integrating a toric correction within a small-aperture optic yields superior optical performance in irregular astigmatism simulations. In clinical practice, combining sulcus-fixated pinhole implants with toric posterior-chamber IOLs or sulcus-fixated toric lenses with a small-aperture posterior-chamber IOL may achieve better outcomes in complex corneal profiles.

Authors

Institutions

Publication Details

Journal
Journal of Cataract & Refractive Surgery
Published
2026-09-09
DOI
https://doi.org/10.1097/j.jcrs.0000000000002059
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Combining Small Aperture Approach and Toric Correction for Irregular Astigmatism Management

Hyeck-Soo Son, Maximilian Friedrich, Asu Rayamajhi, Gerd U. Auffarth et al.
Journal of Cataract & Refractive Surgery
Ophthalmology and Visual Impairment Studies
article

Combining Small Aperture Approach and Toric Correction for Irregular Astigmatism Management

Hyeck-Soo Son, Maximilian Friedrich, Asu Rayamajhi, Gerd U. Auffarth, Ramin Khoramnia, Victor A. Augustin, Grzegorz Łabuz, Ava Niknahad
article en

Abstract

Purpose: Irregular astigmatism poses a challenge in cataract surgery due to its complex geometry and associated higher-order aberrations (HOAs), which limit the efficacy of conventional toric intraocular lenses (IOLs). IOLs featuring a small-aperture have shown promise in managing such cases through the “pinhole effect,” yet they do not correct the underlying astigmatic power. This study investigates the potential of a hybrid IOL design featuring both small-aperture and toric elements to address these limitations. Setting: David J. Apple Laboratory for Ocular Pathology. Design: Experimental study. Methods: A retrospective analysis of 22 eyes with irregular astigmatism was conducted using semi-personalized eye models derived from Pentacam (Oculus) tomography data. Simulations were performed in OpticStudio to evaluate three IOL systems: a toric IOL, a small-aperture, and a combined small-aperture+toric IOL. Image quality was assessed using Strehl Ratio (SR) and RMS error. Landolt C simulations and correlation analyses were also performed. Results: The hybrid IOL significantly outperformed the toric and small-aperture IOLs alone, achieving mean SR of 0.80±0.17 (vs. 0.10±0.07 and 0.20±0.19, respectively, p<0.001 ) and the lowest RMS error (0.07 µm, p<0.001 ). Simulations demonstrated superior visual quality and less sensitivity to corneal asymmetry. R 2 analyses confirmed a strong association between corneal astigmatism and improved optical quality in the combined model. Conclusions: Integrating a toric correction within a small-aperture optic yields superior optical performance in irregular astigmatism simulations. In clinical practice, combining sulcus-fixated pinhole implants with toric posterior-chamber IOLs or sulcus-fixated toric lenses with a small-aperture posterior-chamber IOL may achieve better outcomes in complex corneal profiles.

Journal of Cataract & Refractive Surgery
Karlsruhe Institute of Technology (DE), Johns Hopkins University (US), Heidelberg University (DE), Johns Hopkins Medicine (US), Augenklinik Heidelberg (DE), University Hospital Carl Gustav Carus (DE)
Openalex Percentile: Top 10%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.