Evaluation of FatNav‐Based Prospective Motion Correction for Perivascular Space Imaging With T2‐Weighted MRI at 7 T

ABSTRACT Subject motion during MRI acquisition is one of the major factors limiting image quality and diagnostic value. Previous studies have demonstrated the effectiveness of prospective motion correction (PMC) in mitigating motion‐related artifacts. However, the effectiveness of PMC for the visualization of perivascular spaces (PVS) has not yet been systematically evaluated in clinical populations. PVS imaging was performed using a T2‐weighted 3D turbo spin echo (TSE) sequence with fat navigator (FatNav)‐based PMC. Ten healthy participants were scanned with and without PMC while performing gradual instructed motion. To further evaluate the effectiveness of PMC in a clinical setting, 62 patients were scanned after being instructed to keep their heads still. Among them, 28 patients underwent paired PMC‐on and PMC‐off scans, whereas 34 patients underwent PMC‐on scans only. The degree of motion and its impact on overall image quality was assessed by two experienced radiologists using a 4‐point Likert scale. Quantitative metrics were further evaluated including structural similarity index measure (SSIM), peak signal‐to‐noise ratio (PSNR), PVS count, PVS volume, and contrast‐to‐noise ratio (CNR) between PVS and neighboring tissue. The motion scores were significantly larger in subjects with instructed motion than in patients with involuntary motion (10.3 ± 5.3 mm vs. 1.47 ± 0.97 mm). For instructed motion, PMC significantly improved visual scores and quantitative metrics and weakened negative correlations between motion and the metrics. For involuntary motion, PMC significantly increased CNR ( p < 0.001) and attenuated negative correlations between visual score and motion severity. The improvement in PVS CNR after PMC correlated strongly with motion score ( = 0.40, p = 0.04). However, no significant difference was observed in PVS count and volume between images with and without PMC. In conclusion, FatNav‐based PMC improved the motion robustness of 3D TSE images and PVS quantification in the presence of substantial motion, whereas its benefits for small involuntary motion appeared to be limited.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-09-09
DOI
https://doi.org/10.1002/nbm.70394
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Evaluation of FatNav‐Based Prospective Motion Correction for Perivascular Space Imaging With T2‐Weighted MRI at 7 T

Caohui Duan, Xin Lou, Yichen Zhou, Xiaopeng Zong et al.
NMR in Biomedicine
Cerebrospinal fluid and hydrocephalus
article

Evaluation of FatNav‐Based Prospective Motion Correction for Perivascular Space Imaging With T2‐Weighted MRI at 7 T

Caohui Duan, Xin Lou, Yichen Zhou, Xiaopeng Zong, Yumeng Li, Bingbing Zhao, Minqiang Jia, Hengheng Wu
article en

Abstract

ABSTRACT Subject motion during MRI acquisition is one of the major factors limiting image quality and diagnostic value. Previous studies have demonstrated the effectiveness of prospective motion correction (PMC) in mitigating motion‐related artifacts. However, the effectiveness of PMC for the visualization of perivascular spaces (PVS) has not yet been systematically evaluated in clinical populations. PVS imaging was performed using a T2‐weighted 3D turbo spin echo (TSE) sequence with fat navigator (FatNav)‐based PMC. Ten healthy participants were scanned with and without PMC while performing gradual instructed motion. To further evaluate the effectiveness of PMC in a clinical setting, 62 patients were scanned after being instructed to keep their heads still. Among them, 28 patients underwent paired PMC‐on and PMC‐off scans, whereas 34 patients underwent PMC‐on scans only. The degree of motion and its impact on overall image quality was assessed by two experienced radiologists using a 4‐point Likert scale. Quantitative metrics were further evaluated including structural similarity index measure (SSIM), peak signal‐to‐noise ratio (PSNR), PVS count, PVS volume, and contrast‐to‐noise ratio (CNR) between PVS and neighboring tissue. The motion scores were significantly larger in subjects with instructed motion than in patients with involuntary motion (10.3 ± 5.3 mm vs. 1.47 ± 0.97 mm). For instructed motion, PMC significantly improved visual scores and quantitative metrics and weakened negative correlations between motion and the metrics. For involuntary motion, PMC significantly increased CNR ( p < 0.001) and attenuated negative correlations between visual score and motion severity. The improvement in PVS CNR after PMC correlated strongly with motion score ( = 0.40, p = 0.04). However, no significant difference was observed in PVS count and volume between images with and without PMC. In conclusion, FatNav‐based PMC improved the motion robustness of 3D TSE images and PVS quantification in the presence of substantial motion, whereas its benefits for small involuntary motion appeared to be limited.

NMR in BiomedicineVol. 39(10)
Chinese PLA General Hospital (CN), ShanghaiTech University (CN), Shanghai Clinical Research Center (CN)
Openalex Percentile: Top 16%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.