Balloon-assisted radial release for retrieval of a surgically suture-fixed inferior vena cava filter: a case report

The retrieval of an inferior vena cava (IVC) filter is essential for preventing complications related to the filter. Surgically induced suture fixation is an extremely rare cause of filter entrapment and presents unique technical challenges. This case describes a balloon-assisted radial release within the filter frame followed by snare retrieval to successfully address this condition. We report a rare case of successful retrieval of a surgically suture-fixed inferior vena cava filter via femoral venous access using a balloon-assisted radial release technique combined with snare retrieval, which has not been previously reported. An endovascular strategy of “release first, then retrieval” was adopted. Sequential balloon dilations were performed to achieve controlled radial expansion and mechanical release at the fixation site. Following controlled strut fracture and resolution of the external constraint, the filter was completely retrieved using a snare technique under large-sheath protection. The balloon-assisted radial release technique may provide a minimally invasive solution for the retrieval of inferior vena cava filters fixed by surgical sutures.

Authors

Institutions

Publication Details

Journal
Thrombosis Journal
Published
2026-09-09
DOI
https://doi.org/10.1186/s12959-026-00913-1
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Balloon-assisted radial release for retrieval of a surgically suture-fixed inferior vena cava filter: a case report

Huanliang Liu, Xuanfeng Zhu, Peng Gao, Jindi Wei et al.
Thrombosis Journal
Venous Thromboembolism Diagnosis and Management
article

Balloon-assisted radial release for retrieval of a surgically suture-fixed inferior vena cava filter: a case report

Huanliang Liu, Xuanfeng Zhu, Peng Gao, Jindi Wei, Xiquan Zhang
article en

Abstract

The retrieval of an inferior vena cava (IVC) filter is essential for preventing complications related to the filter. Surgically induced suture fixation is an extremely rare cause of filter entrapment and presents unique technical challenges. This case describes a balloon-assisted radial release within the filter frame followed by snare retrieval to successfully address this condition. We report a rare case of successful retrieval of a surgically suture-fixed inferior vena cava filter via femoral venous access using a balloon-assisted radial release technique combined with snare retrieval, which has not been previously reported. An endovascular strategy of “release first, then retrieval” was adopted. Sequential balloon dilations were performed to achieve controlled radial expansion and mechanical release at the fixation site. Following controlled strut fracture and resolution of the external constraint, the filter was completely retrieved using a snare technique under large-sheath protection. The balloon-assisted radial release technique may provide a minimally invasive solution for the retrieval of inferior vena cava filters fixed by surgical sutures.

Thrombosis Journal
Weifang Medical University (CN), Central Hospital of Zibo (CN)
Openalex Percentile: Top 9%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Balloon-assisted radial release for retrieval of a surgically suture-fixed inferior vena cava filter: a case report — Huanliang Liu, Xuanfeng Zhu, et al. · Thrombosis Journal (2026) | TGRS Research Map | TGRS