Measurement Differences Between Markerless Motion Capture Systems During Sit-to-Stand Performance: Implications for Clinical Interpretation and Physical Therapy Education

Background: Markerless motion capture systems are increasingly used in clinical and educational settings to assess functional movement. However, differences in system design and data processing may influence measurement outputs, raising questions about the systematic differences in these technologies. Methods: A within-subject, repeated-measures design was used to compare range of motion (ROM) measurements obtained from two markerless motion capture systems during a sit-to-stand task. Fifty healthy adults (18–50 years) performed the task under three surface conditions (firm, compliant, and commode) while both systems recorded movement simultaneously. Joint ROM at the trunk, hips, knees, and ankles was analyzed using linear mixed-effects modeling to examine device, surface, and interaction effects. ROM was standardized to account for differences in absolute ROM magnitude and variability across biomechanically distinct joint measures. Results: A linear mixed-effects model showed significant main effects of both Device and Surface (all p’s < 0.001). There were also significant interactions between Device × Surface (p = 0.032), Device × Joint (p < 0.001), and Surface × Joint (p < 0.001), indicating that differences between devices and surfaces varied across biomechanical measures. The device-related discrepancies in standardized ROM (zROM) were greatest for hip adduction and trunk forward lean, whereas smaller between system differences were observed for ankle dorsiflexion and knee flexion. The firm surface demonstrated relatively larger zROM measurements for ankle dorsiflexion, knee flexion, and hip flexion compared to the compliant and commode surfaces. Conclusions: Markerless motion capture systems produced systematically different measurements during a functional task, and these differences were influenced by movement type and task conditions. The findings suggest that kinematic data derived from different markerless motion capture systems should be interpreted cautiously when comparing movement performance. Consistent use of a single system may be important for clinical tracking, and educational programs should emphasize critical interpretation of technology-derived movement data.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-09-08
DOI
https://doi.org/10.3390/app16188906
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Differences Between Markerless Motion Capture Systems During Sit-to-Stand Performance: Implications for Clinical Interpretation and Physical Therapy Education

Christopher Voltmer, Casey M. Imperio, Mark Apostol
Applied Sciences
Balance, Gait, and Falls Prevention
article

Measurement Differences Between Markerless Motion Capture Systems During Sit-to-Stand Performance: Implications for Clinical Interpretation and Physical Therapy Education

Christopher Voltmer, Casey M. Imperio, Mark Apostol
article en

Abstract

Background: Markerless motion capture systems are increasingly used in clinical and educational settings to assess functional movement. However, differences in system design and data processing may influence measurement outputs, raising questions about the systematic differences in these technologies. Methods: A within-subject, repeated-measures design was used to compare range of motion (ROM) measurements obtained from two markerless motion capture systems during a sit-to-stand task. Fifty healthy adults (18–50 years) performed the task under three surface conditions (firm, compliant, and commode) while both systems recorded movement simultaneously. Joint ROM at the trunk, hips, knees, and ankles was analyzed using linear mixed-effects modeling to examine device, surface, and interaction effects. ROM was standardized to account for differences in absolute ROM magnitude and variability across biomechanically distinct joint measures. Results: A linear mixed-effects model showed significant main effects of both Device and Surface (all p’s < 0.001). There were also significant interactions between Device × Surface (p = 0.032), Device × Joint (p < 0.001), and Surface × Joint (p < 0.001), indicating that differences between devices and surfaces varied across biomechanical measures. The device-related discrepancies in standardized ROM (zROM) were greatest for hip adduction and trunk forward lean, whereas smaller between system differences were observed for ankle dorsiflexion and knee flexion. The firm surface demonstrated relatively larger zROM measurements for ankle dorsiflexion, knee flexion, and hip flexion compared to the compliant and commode surfaces. Conclusions: Markerless motion capture systems produced systematically different measurements during a functional task, and these differences were influenced by movement type and task conditions. The findings suggest that kinematic data derived from different markerless motion capture systems should be interpreted cautiously when comparing movement performance. Consistent use of a single system may be important for clinical tracking, and educational programs should emphasize critical interpretation of technology-derived movement data.

Applied SciencesVol. 16(18)
Touro College (US)
Quality Education
Openalex Percentile: Top 5%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.