Error Direction of Large Language Models on Medical Multiple-Response Questions: Opportunity-Standardized Benchmark Study

Background Large language models (LLMs) attain high accuracy on medical examinations, yet evaluations rely predominantly on single-best-answer multiple-choice questions and report only overall accuracy. Multiple-response items, termed X-type in China, require selecting every correct option and remain understudied. Whether models err by omitting correct options or by commissioning incorrect ones has yet to be assessed within an opportunity-standardized framework. Objective This study aimed to quantify the accuracy penalty of multiple-response (X-type) items relative to single-select items and to determine, after standardizing for the unequal numbers of correct and incorrect options, whether LLMs lean toward omission or commission. Methods We analyzed 1644 text-based items from 10 examination cohorts (2017‐2026) of the Chinese National Postgraduate Entrance Examination in Clinical Medicine, comprising 1344 single-select items of types A1, A2, A3, and B, and 300 X-type items. Five LLMs, DeepSeek V4 Pro, Kimi K3, Doubao Seed-2.1-pro, GPT-5.6 Sol, and Gemini-3.6 Flash, were tested zero-shot bilingually, yielding 16,440 planned responses. Item-type effects were estimated using generalized estimating equations with cluster-robust standard errors, adjusting for model, language, discipline, and cohort. Opportunity-standardized error direction was analyzed 2 ways: an option-level model treating each option as 1 judgment record and the omission-bias index. Results Of 16,440 planned responses, 16,426 (99.91%) were evaluable. X-type accuracy (2527/3000, 84.23%) was markedly below single-select accuracy (12,990/13,426, 96.75%; adjusted odds ratio at GPT-5.6 Sol in Chinese 0.17, 95% CI 0.11‐0.26; P <.001), a gap of 12.52 percentage points observed and 13.55 adjusted, with no statistically significant item type × model or item type × language interaction ( P =.19 and P =.82). Raw counts suggested more strict omissions (245/3000, 8.17%) than overselections (201/3000, 6.70%), but X-type items averaged 2.79 correct vs 1.21 incorrect options per item, a 2.3-fold imbalance in error opportunities. After opportunity standardization, the per-opportunity false-selection rate was 6.69% (242/3620), roughly twice the 3.57% per-opportunity omission rate (299/8380; rate ratio 1.87, 95% CI 1.28‐2.74; adjusted odds ratio at the reference model and language 0.38, 95% CI 0.20‐0.70; P =.002), so the tilt is modest on the absolute scale and close to 2-fold on the relative scale. Strict omission showed no between-model difference (all Holm-adjusted pairwise comparisons, P ≥.46). Conclusions LLMs incur a substantial accuracy penalty on medical multiple-response items. The apparent omission dominance in raw counts is an artifact of answer-key opportunity imbalance; after opportunity standardization, models show a commission tilt that is modest on the absolute scale (3.12 percentage points per opportunity) and close to 2-fold on the relative scale, and that holds in every model-language condition and in the answer-key stratum whose opportunity base is exactly balanced. Medical LLM benchmarks should report accuracy stratified by item type and error direction on an opportunity-standardized basis.

Authors

Publication Details

Journal
JMIR Medical Education
Published
2026-11-23
DOI
https://doi.org/10.2196/111146
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Error Direction of Large Language Models on Medical Multiple-Response Questions: Opportunity-Standardized Benchmark Study

Haolin Yin, Mengqian Liao, Xinyan Ran, Shanshan Duan et al.
7 links
JMIR Medical Education
Artificial Intelligence in Healthcare and Education
article

Error Direction of Large Language Models on Medical Multiple-Response Questions: Opportunity-Standardized Benchmark Study

Haolin Yin, Mengqian Liao, Xinyan Ran, Shanshan Duan, Xia Luo, Yueming Yang, Yang Liu
article en

Abstract

Background Large language models (LLMs) attain high accuracy on medical examinations, yet evaluations rely predominantly on single-best-answer multiple-choice questions and report only overall accuracy. Multiple-response items, termed X-type in China, require selecting every correct option and remain understudied. Whether models err by omitting correct options or by commissioning incorrect ones has yet to be assessed within an opportunity-standardized framework. Objective This study aimed to quantify the accuracy penalty of multiple-response (X-type) items relative to single-select items and to determine, after standardizing for the unequal numbers of correct and incorrect options, whether LLMs lean toward omission or commission. Methods We analyzed 1644 text-based items from 10 examination cohorts (2017‐2026) of the Chinese National Postgraduate Entrance Examination in Clinical Medicine, comprising 1344 single-select items of types A1, A2, A3, and B, and 300 X-type items. Five LLMs, DeepSeek V4 Pro, Kimi K3, Doubao Seed-2.1-pro, GPT-5.6 Sol, and Gemini-3.6 Flash, were tested zero-shot bilingually, yielding 16,440 planned responses. Item-type effects were estimated using generalized estimating equations with cluster-robust standard errors, adjusting for model, language, discipline, and cohort. Opportunity-standardized error direction was analyzed 2 ways: an option-level model treating each option as 1 judgment record and the omission-bias index. Results Of 16,440 planned responses, 16,426 (99.91%) were evaluable. X-type accuracy (2527/3000, 84.23%) was markedly below single-select accuracy (12,990/13,426, 96.75%; adjusted odds ratio at GPT-5.6 Sol in Chinese 0.17, 95% CI 0.11‐0.26; P <.001), a gap of 12.52 percentage points observed and 13.55 adjusted, with no statistically significant item type × model or item type × language interaction ( P =.19 and P =.82). Raw counts suggested more strict omissions (245/3000, 8.17%) than overselections (201/3000, 6.70%), but X-type items averaged 2.79 correct vs 1.21 incorrect options per item, a 2.3-fold imbalance in error opportunities. After opportunity standardization, the per-opportunity false-selection rate was 6.69% (242/3620), roughly twice the 3.57% per-opportunity omission rate (299/8380; rate ratio 1.87, 95% CI 1.28‐2.74; adjusted odds ratio at the reference model and language 0.38, 95% CI 0.20‐0.70; P =.002), so the tilt is modest on the absolute scale and close to 2-fold on the relative scale. Strict omission showed no between-model difference (all Holm-adjusted pairwise comparisons, P ≥.46). Conclusions LLMs incur a substantial accuracy penalty on medical multiple-response items. The apparent omission dominance in raw counts is an artifact of answer-key opportunity imbalance; after opportunity standardization, models show a commission tilt that is modest on the absolute scale (3.12 percentage points per opportunity) and close to 2-fold on the relative scale, and that holds in every model-language condition and in the answer-key stratum whose opportunity base is exactly balanced. Medical LLM benchmarks should report accuracy stratified by item type and error direction on an opportunity-standardized basis.

JMIR Medical EducationVol. 12
Good health and well-being
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon