Mode Prioritization for Vibration-Based Condition Monitoring: A Laboratory Sensitivity and Consistency Assessment of Damaged Aluminum Cantilever Beams

Vibration-based condition monitoring of beam-like metallic components requires vibration modes that are both sensitive to damage and consistent across different damage locations and severities. This study evaluates the damage sensitivity of the first eight bending-mode frequencies measured from 19 aluminum-alloy 6063 cantilever beams instrumented with magnetoelastic vibration sensors. The examined configurations comprised one undamaged reference beam and 18 damaged beams combining six crack-like defect locations with three defect depths. Normalized absolute frequency shifts were used to determine the mean sensitivity of each mode, its response to increasing defect depth, and the consistency of this response across the examined locations. The combined modal response increased progressively with defect depth, although the magnitude of the change depended on the selected mode and defect location. Mode f7 exhibited the highest mean sensitivity of 1.234%and amonotonic-consistency ratio of C7=1, indicating an increasing response with defect depth at all six locations. Modes f2 and f4 also demonstrated complete monotonic consistency but lower overall sensitivity, whereas f5 showed comparatively high sensitivity with greater dependence on defect location. Mode f8 presented the lowest sensitivity and consistency. These findings indicate that the available modes do not need to be treated equally. Prioritizing modes that combine high sensitivity with consistent depth-dependent behavior could simplify the processing and interpretation of modal information for preliminary condition monitoring of metallic industrial components. Further repeated measurements and validation under operational conditions are required before diagnostic thresholds can be established.

Authors

Publication Details

Journal
Industries
Published
2026-11-06
DOI
https://doi.org/10.3390/industries1020013
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mode Prioritization for Vibration-Based Condition Monitoring: A Laboratory Sensitivity and Consistency Assessment of Damaged Aluminum Cantilever Beams

Georgios Samourgkanidis
Industries
Structural Health Monitoring Techniques
article

Mode Prioritization for Vibration-Based Condition Monitoring: A Laboratory Sensitivity and Consistency Assessment of Damaged Aluminum Cantilever Beams

Georgios Samourgkanidis
article en

Abstract

Vibration-based condition monitoring of beam-like metallic components requires vibration modes that are both sensitive to damage and consistent across different damage locations and severities. This study evaluates the damage sensitivity of the first eight bending-mode frequencies measured from 19 aluminum-alloy 6063 cantilever beams instrumented with magnetoelastic vibration sensors. The examined configurations comprised one undamaged reference beam and 18 damaged beams combining six crack-like defect locations with three defect depths. Normalized absolute frequency shifts were used to determine the mean sensitivity of each mode, its response to increasing defect depth, and the consistency of this response across the examined locations. The combined modal response increased progressively with defect depth, although the magnitude of the change depended on the selected mode and defect location. Mode f7 exhibited the highest mean sensitivity of 1.234%and amonotonic-consistency ratio of C7=1, indicating an increasing response with defect depth at all six locations. Modes f2 and f4 also demonstrated complete monotonic consistency but lower overall sensitivity, whereas f5 showed comparatively high sensitivity with greater dependence on defect location. Mode f8 presented the lowest sensitivity and consistency. These findings indicate that the available modes do not need to be treated equally. Prioritizing modes that combine high sensitivity with consistent depth-dependent behavior could simplify the processing and interpretation of modal information for preliminary condition monitoring of metallic industrial components. Further repeated measurements and validation under operational conditions are required before diagnostic thresholds can be established.

IndustriesVol. 1(2)
Openalex Percentile: Top 44%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon