Atrial Fibrillation Ablation Technology Adoption and Procedural Metrics: An 11-Year Longitudinal Service Evaluation at a UK Tertiary Centre

Background: Contemporary AF ablation practice has changed rapidly with the introduction of newer energy-delivery platforms. How these changes translate into longitudinal patterns of technology use and procedural characteristics within routine electrophysiology services is less well described. Methods: We performed a retrospective, procedure-level longitudinal service evaluation of AF ablations performed between April 2014 and June 2025 at a United Kingdom (UK) tertiary center. Index and repeat procedures were included. We describe annual technology use and observed skin-to-skin procedure time, fluoroscopy time, and dose-area product (DAP). These are operational measures, not surrogate clinical endpoints. We undertook no adjusted comparative analysis because technology choice was coupled with calendar era and relevant clinical and operator-level covariates were incomplete. Results: The analysis included 2862 procedures, comprising 1878 (66%) radiofrequency ablation (RFA), 735 (26%) cryoballoon, and 249 (9%) pulsed field ablation (PFA). RFA remained the predominant approach until 2020, cryoballoon use peaked in 2018 (n = 138), and PFA increased from 56 procedures in 2023 to 98 in 2024 and 95 in the first half of 2025. The median skin-to-skin time changed from 205 min in 2014 to 104 min in 2025. Observed median fluoroscopy time changed from 32 to 13 min, and median DAP from 3405 to 782 Gy.cm2. Conclusions: Over 11 years, the centre experienced a marked change in AF ablation practice, characterised by the progressive adoption of newer technologies, alongside lower recorded procedure durations and radiation exposure. These observations describe service-level temporal trends and should not be interpreted as evidence that any individual ablation modality caused the observed changes or improved clinical outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-09-06
DOI
https://doi.org/10.3390/jcm15176894
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Atrial Fibrillation Ablation Technology Adoption and Procedural Metrics: An 11-Year Longitudinal Service Evaluation at a UK Tertiary Centre

Ibrahim Antoun, G. André Ng, Mokhtar Ibrahim, Zakariyya Vali et al.
Journal of Clinical Medicine
Atrial Fibrillation Management and Outcomes
article

Atrial Fibrillation Ablation Technology Adoption and Procedural Metrics: An 11-Year Longitudinal Service Evaluation at a UK Tertiary Centre

Ibrahim Antoun, G. André Ng, Mokhtar Ibrahim, Zakariyya Vali, Ahmed Abdelrazik, Sharon Man, Thet Su Su, Riyaz Somani, Kaung Myat Thu, Mahmoud Eldesouky
article en

Abstract

Background: Contemporary AF ablation practice has changed rapidly with the introduction of newer energy-delivery platforms. How these changes translate into longitudinal patterns of technology use and procedural characteristics within routine electrophysiology services is less well described. Methods: We performed a retrospective, procedure-level longitudinal service evaluation of AF ablations performed between April 2014 and June 2025 at a United Kingdom (UK) tertiary center. Index and repeat procedures were included. We describe annual technology use and observed skin-to-skin procedure time, fluoroscopy time, and dose-area product (DAP). These are operational measures, not surrogate clinical endpoints. We undertook no adjusted comparative analysis because technology choice was coupled with calendar era and relevant clinical and operator-level covariates were incomplete. Results: The analysis included 2862 procedures, comprising 1878 (66%) radiofrequency ablation (RFA), 735 (26%) cryoballoon, and 249 (9%) pulsed field ablation (PFA). RFA remained the predominant approach until 2020, cryoballoon use peaked in 2018 (n = 138), and PFA increased from 56 procedures in 2023 to 98 in 2024 and 95 in the first half of 2025. The median skin-to-skin time changed from 205 min in 2014 to 104 min in 2025. Observed median fluoroscopy time changed from 32 to 13 min, and median DAP from 3405 to 782 Gy.cm2. Conclusions: Over 11 years, the centre experienced a marked change in AF ablation practice, characterised by the progressive adoption of newer technologies, alongside lower recorded procedure durations and radiation exposure. These observations describe service-level temporal trends and should not be interpreted as evidence that any individual ablation modality caused the observed changes or improved clinical outcomes.

Journal of Clinical MedicineVol. 15(17)
University of Leicester (GB), Glenfield Hospital (GB), University Hospitals of Leicester NHS Trust (GB), British Heart Foundation (GB), NIHR Leicester Biomedical Research Centre (GB), University Hospitals Plymouth NHS Trust (GB)
Affordable and clean energy
Openalex Percentile: Top 10%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.