Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

Shiqi Jiang,1,2,* Yan Chen,1,2,* Lu Cao,1 Haoxin Fu,1 Peiqi Wang,1 Chongmeng Yang31Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 2Zhejiang Key Laboratory of Intelligent Cancer Biomarker Discovery and Translation, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 3Department of Ophthalmology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China*These authors contributed equally to this workCorrespondence: Chongmeng Yang, Email [email protected]: Ensartinib is a second-generation anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitor approved for the treatment of ALK-positive non-small cell lung cancer (NSCLC). However, its in vivo disposition and metabolic characteristics, particularly those of its major metabolite M465, remain incompletely understood. This study aimed to develop and validate a sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method for the simultaneous quantification of ensartinib and M465 in rat plasma and to apply the method to a pharmacokinetic study in rats.Methods: Crizotinib was used as the internal standard (IS). Plasma samples were processed by one-step protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters Acquity BEH C18 column using gradient elution with 0.1% formic acid in water and acetonitrile. The method was validated in terms of selectivity, linearity, lower limit of quantification (LLOQ), precision, accuracy, recovery, matrix effect, stability, carry-over and dilution integrity. The validated method was subsequently applied to determine plasma concentrations of ensartinib and M465 after oral administration of ensartinib to rats.Results: The method showed good linearity over the concentration ranges of 0.1– 100 ng/mL for ensartinib and 0.05– 10 ng/mL for M465, with LLOQs of 0.1 ng/mL and 0.05 ng/mL, respectively. The intra- and inter-day precision values ranged from 2.2% to 16.4%, and the accuracy ranged from − 12.3% to 8.0%, meeting the acceptance criteria for bioanalytical method validation. Recovery, matrix effect, stability, carry-over and dilution integrity were all within acceptable limits. After oral administration of ensartinib to rats, the maximum plasma concentrations (Cmax) of ensartinib and M465 were approximately 64.7 ng/mL and 6.3 ng/mL, respectively. The AUC(0–t) values of ensartinib and M465 were 577.6 ng/mL*h and 32.5 ng/mL*h, respectively, indicating lower systemic exposure of M465 compared with the parent drug.Conclusion: A sensitive, reliable, and rapid UPLC–MS/MS method was successfully developed and validated for the simultaneous determination of ensartinib and M465 in rat plasma. The method was successfully applied to a rat pharmacokinetic study and provides useful analytical support for further preclinical investigations of ensartinib and its major metabolite.Keywords: ensartinib, M465, pharmacokinetics, UPLC–MS/MS, rat

Authors

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2026-09-05
Primary Topic
Lung Cancer Treatments and Mutations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

Chongmeng Yang, Haoxin Fu, Shiqi Jiang, Peiqi Wang et al.
Dove Medical Press (Taylor and Francis Group)
Lung Cancer Treatments and Mutations
article

Development and Validation of a UPLC–MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies

Chongmeng Yang, Haoxin Fu, Shiqi Jiang, Peiqi Wang, Lu Cao, Yan Chen
article en

Abstract

Shiqi Jiang,1,2,* Yan Chen,1,2,* Lu Cao,1 Haoxin Fu,1 Peiqi Wang,1 Chongmeng Yang31Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 2Zhejiang Key Laboratory of Intelligent Cancer Biomarker Discovery and Translation, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China; 3Department of Ophthalmology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People’s Republic of China*These authors contributed equally to this workCorrespondence: Chongmeng Yang, Email [email protected]: Ensartinib is a second-generation anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitor approved for the treatment of ALK-positive non-small cell lung cancer (NSCLC). However, its in vivo disposition and metabolic characteristics, particularly those of its major metabolite M465, remain incompletely understood. This study aimed to develop and validate a sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method for the simultaneous quantification of ensartinib and M465 in rat plasma and to apply the method to a pharmacokinetic study in rats.Methods: Crizotinib was used as the internal standard (IS). Plasma samples were processed by one-step protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters Acquity BEH C18 column using gradient elution with 0.1% formic acid in water and acetonitrile. The method was validated in terms of selectivity, linearity, lower limit of quantification (LLOQ), precision, accuracy, recovery, matrix effect, stability, carry-over and dilution integrity. The validated method was subsequently applied to determine plasma concentrations of ensartinib and M465 after oral administration of ensartinib to rats.Results: The method showed good linearity over the concentration ranges of 0.1– 100 ng/mL for ensartinib and 0.05– 10 ng/mL for M465, with LLOQs of 0.1 ng/mL and 0.05 ng/mL, respectively. The intra- and inter-day precision values ranged from 2.2% to 16.4%, and the accuracy ranged from − 12.3% to 8.0%, meeting the acceptance criteria for bioanalytical method validation. Recovery, matrix effect, stability, carry-over and dilution integrity were all within acceptable limits. After oral administration of ensartinib to rats, the maximum plasma concentrations (Cmax) of ensartinib and M465 were approximately 64.7 ng/mL and 6.3 ng/mL, respectively. The AUC(0–t) values of ensartinib and M465 were 577.6 ng/mL*h and 32.5 ng/mL*h, respectively, indicating lower systemic exposure of M465 compared with the parent drug.Conclusion: A sensitive, reliable, and rapid UPLC–MS/MS method was successfully developed and validated for the simultaneous determination of ensartinib and M465 in rat plasma. The method was successfully applied to a rat pharmacokinetic study and provides useful analytical support for further preclinical investigations of ensartinib and its major metabolite.Keywords: ensartinib, M465, pharmacokinetics, UPLC–MS/MS, rat

Dove Medical Press (Taylor and Francis Group)
Openalex Percentile: Top 11%
Lung Cancer Treatments and Mutations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.