Comparative accuracy of continuous electronic urine output monitoring in the post-cardiac surgery intensive care unit

Abstract Acute kidney injury (AKI) is a serious complication following coronary artery bypass grafting (CABG) and is clinically identified by changes in serum creatinine and urine output (UO). Currently, UO is typically monitored via visual inspection (VI), a method with limited precision. This prospective observational study evaluated the measurement accuracy of a continuous electronic UO monitoring system (Device) compared to VI, using graduated cylinder (GC) measurements as the gold standard. Hourly UO was measured in 52 post-CABG patients in a cardiac ICU (Guilan University of Medical Sciences, Rasht, Iran). For each patient, UO was recorded hourly across all three methods over a 6-hour period, resulting in 936 total measurements (312 per method). Statistical agreement was assessed using Lin’s concordance correlation coefficient (CCC), intraclass correlation coefficients (ICC), and Bland–Altman plots, with analyses adjusted for repeated-measures clustering. The Device demonstrated excellent agreement with the GC (CCC = 0.997; ICC = 0.997), significantly outperforming the VI method (CCC = 0.858; ICC = 0.859). Bland–Altman analysis revealed minimal systematic bias for the Device (mean bias = 4.4 ml; 95% LoA: 0.1 to 8.7 ml) compared to the GC, whereas VI showed notable overestimation (mean bias = 31.2 ml; 95% LoA: -18.2 to 80.7 ml). These results indicate that the electronic monitoring system offers significantly higher accuracy than visual inspection for real-time UO recording in post-CABG patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-09-06
DOI
https://doi.org/10.1038/s41598-026-70497-3
Primary Topic
Acute Kidney Injury Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Comparative accuracy of continuous electronic urine output monitoring in the post-cardiac surgery intensive care unit

Benyamin Alimohammadi, Saman Maroufizadeh, Mohammad-Taghi Moghadamnia, Marzieh Jahani Sayad Noveiri et al.
Scientific Reports
Acute Kidney Injury Research
article

Comparative accuracy of continuous electronic urine output monitoring in the post-cardiac surgery intensive care unit

Benyamin Alimohammadi, Saman Maroufizadeh, Mohammad-Taghi Moghadamnia, Marzieh Jahani Sayad Noveiri, Ezzat Paryad
article en

Abstract

Abstract Acute kidney injury (AKI) is a serious complication following coronary artery bypass grafting (CABG) and is clinically identified by changes in serum creatinine and urine output (UO). Currently, UO is typically monitored via visual inspection (VI), a method with limited precision. This prospective observational study evaluated the measurement accuracy of a continuous electronic UO monitoring system (Device) compared to VI, using graduated cylinder (GC) measurements as the gold standard. Hourly UO was measured in 52 post-CABG patients in a cardiac ICU (Guilan University of Medical Sciences, Rasht, Iran). For each patient, UO was recorded hourly across all three methods over a 6-hour period, resulting in 936 total measurements (312 per method). Statistical agreement was assessed using Lin’s concordance correlation coefficient (CCC), intraclass correlation coefficients (ICC), and Bland–Altman plots, with analyses adjusted for repeated-measures clustering. The Device demonstrated excellent agreement with the GC (CCC = 0.997; ICC = 0.997), significantly outperforming the VI method (CCC = 0.858; ICC = 0.859). Bland–Altman analysis revealed minimal systematic bias for the Device (mean bias = 4.4 ml; 95% LoA: 0.1 to 8.7 ml) compared to the GC, whereas VI showed notable overestimation (mean bias = 31.2 ml; 95% LoA: -18.2 to 80.7 ml). These results indicate that the electronic monitoring system offers significantly higher accuracy than visual inspection for real-time UO recording in post-CABG patients.

Scientific Reports
Guilan University of Medical Sciences (IR), Qazvin University of Medical Sciences (IR)
Good health and well-being
Openalex Percentile: Top 11%
Acute Kidney Injury Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative accuracy of continuous electronic urine output monitoring in the post-cardiac surgery intensive care unit — Benyamin Alimohammadi, Saman Maroufizadeh, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS