Repeatability and behavioral relationships of acuity, contrast sensitivity, form, and motion perception measurements using a novel tablet-based vision test tool

Abstract Visual function tests are essential in basic and clinical vision research but are typically restricted to a limited range of visual functions and provide coarse diagnostic resolution. The response-adaptive Angular Indication Measurement (AIM) and Foraging Interactive D-prime (FInD) paradigms were recently developed as generalizable approaches for assessing multiple visual functions. Both methods present 4 × 4 stimulus arrays spanning ± 2σ around an adaptively estimated threshold. This study evaluated the repeatability, test duration, and relationships between AIM and FInD measures of near visual acuity (VA), contrast sensitivity function (CSF), and form and motion coherence using tablet-based vision tests. 38 healthy participants completed two repetitions of each test in random order. Bland–Altman analyses were used to determine the coefficient of repeatability (CoR), standard error of measurement (SEM), and mean bias. Linear regression and hierarchical cluster analyses examined relationships between outcome measures. Coherence-based outcomes (form and motion) showed comparatively lower individual-level precision despite the general absence of retest bias, whereas all other measures were bias-free. VA demonstrated the highest individual-level precision, CSF precision improved with additional adaptive charts, and coherence measures exhibited lower precision despite minimal retest bias. Mean test duration ranged from 92 s (VA) to 360 s (Form coherence). Exploratory cluster analysis grouped form and motion coherence outcomes separately from AULCSF. Motion coherence measures showed correlations before correction for multiple comparisons, whereas AULCSF did not correlate significantly with any other outcome. AIM and FInD provide generalizable, response-adaptive assessments across multiple visual functions, with repeatability dependent on the outcome measure, supporting their potential for both research and clinical applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-09-07
DOI
https://doi.org/10.1038/s41598-026-68434-5
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability and behavioral relationships of acuity, contrast sensitivity, form, and motion perception measurements using a novel tablet-based vision test tool

Peter J. Bex, Jan Skerswetat, Gunnar Schmidtmann, Jonathan Green
Scientific Reports
Ophthalmology and Visual Impairment Studies
article

Repeatability and behavioral relationships of acuity, contrast sensitivity, form, and motion perception measurements using a novel tablet-based vision test tool

Peter J. Bex, Jan Skerswetat, Gunnar Schmidtmann, Jonathan Green
article en

Abstract

Abstract Visual function tests are essential in basic and clinical vision research but are typically restricted to a limited range of visual functions and provide coarse diagnostic resolution. The response-adaptive Angular Indication Measurement (AIM) and Foraging Interactive D-prime (FInD) paradigms were recently developed as generalizable approaches for assessing multiple visual functions. Both methods present 4 × 4 stimulus arrays spanning ± 2σ around an adaptively estimated threshold. This study evaluated the repeatability, test duration, and relationships between AIM and FInD measures of near visual acuity (VA), contrast sensitivity function (CSF), and form and motion coherence using tablet-based vision tests. 38 healthy participants completed two repetitions of each test in random order. Bland–Altman analyses were used to determine the coefficient of repeatability (CoR), standard error of measurement (SEM), and mean bias. Linear regression and hierarchical cluster analyses examined relationships between outcome measures. Coherence-based outcomes (form and motion) showed comparatively lower individual-level precision despite the general absence of retest bias, whereas all other measures were bias-free. VA demonstrated the highest individual-level precision, CSF precision improved with additional adaptive charts, and coherence measures exhibited lower precision despite minimal retest bias. Mean test duration ranged from 92 s (VA) to 360 s (Form coherence). Exploratory cluster analysis grouped form and motion coherence outcomes separately from AULCSF. Motion coherence measures showed correlations before correction for multiple comparisons, whereas AULCSF did not correlate significantly with any other outcome. AIM and FInD provide generalizable, response-adaptive assessments across multiple visual functions, with repeatability dependent on the outcome measure, supporting their potential for both research and clinical applications.

Scientific Reports
Northeastern University (US), University of California, Irvine (US), University of Plymouth (GB)
College of Optometrists, National Institutes of Health
Openalex Percentile: Top 10%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.