Suspended patient-specific instrument-assisted femur-first osteotomy for fixed-bearing unicompartmental knee arthroplasty: technical note and preliminary clinical results

This study designed a novel suspended patient-specific instrument (SPSI), described its design rationale and the surgical workflow of femur-first osteotomy based on this instrument, and explored its feasibility and early clinical outcomes in fixed-bearing unicompartmental knee arthroplasty (UKA). Ten patients with anteromedial osteoarthritis of the knee were included, all of whom underwent UKA with SPSI-assisted femur-first osteotomy. Operative time, blood loss, and postoperative complications were recorded. The resting pain VAS score and the objective knee component of the 2011 revised KSS were compared preoperatively and at 3 months postoperatively, and prosthetic positioning parameters were assessed via X-ray. All surgeries were completed successfully without abandonment of the SPSI or severe complications. The median operative time was 75.00 (70.00, 96.75) minutes, and the median blood loss was 50.00 (50.00, 62.50) ml. At 3 months postoperatively, the VAS score decreased significantly from 5.50 (5.00, 6.25) preoperatively to 0.50 (0.00, 1.00) ( p = 0.005), while the KSS score improved significantly from 44.40 ± 4.67 preoperatively to 80.90 ± 5.45 ( p < 0.001). Satisfactory prosthetic positioning parameters were achieved, with a femoral coronal angle of 89.70 ± 6.78°, a tibial coronal angle of 86.80 ± 2.20°, a femoral sagittal angle of 8.40 ± 1.89°, and a tibial sagittal angle of 82.00 ± 2.49°. The SPSI enables accurate localization of femoral prosthesis peg holes, and the femur-first osteotomy workflow optimizes the surgical field and simplifies intraoperative steps. Current preliminary data indicate this novel workflow may serve as a feasible alternative for fixed-bearing UKA, though comparative analysis and long-term survivorship data remain absent.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2026-09-07
DOI
https://doi.org/10.1186/s13018-026-07226-z
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suspended patient-specific instrument-assisted femur-first osteotomy for fixed-bearing unicompartmental knee arthroplasty: technical note and preliminary clinical results

Huantang Zhang, Yingdong Ye, Changyu Huang, Zhikun Zhuang et al.
Journal of Orthopaedic Surgery and Research
Total Knee Arthroplasty Outcomes
article

Suspended patient-specific instrument-assisted femur-first osteotomy for fixed-bearing unicompartmental knee arthroplasty: technical note and preliminary clinical results

Huantang Zhang, Yingdong Ye, Changyu Huang, Zhikun Zhuang, Zhi-Bing Gong, Xian-Liang Lai, Zixin Guo
article en

Abstract

This study designed a novel suspended patient-specific instrument (SPSI), described its design rationale and the surgical workflow of femur-first osteotomy based on this instrument, and explored its feasibility and early clinical outcomes in fixed-bearing unicompartmental knee arthroplasty (UKA). Ten patients with anteromedial osteoarthritis of the knee were included, all of whom underwent UKA with SPSI-assisted femur-first osteotomy. Operative time, blood loss, and postoperative complications were recorded. The resting pain VAS score and the objective knee component of the 2011 revised KSS were compared preoperatively and at 3 months postoperatively, and prosthetic positioning parameters were assessed via X-ray. All surgeries were completed successfully without abandonment of the SPSI or severe complications. The median operative time was 75.00 (70.00, 96.75) minutes, and the median blood loss was 50.00 (50.00, 62.50) ml. At 3 months postoperatively, the VAS score decreased significantly from 5.50 (5.00, 6.25) preoperatively to 0.50 (0.00, 1.00) ( p = 0.005), while the KSS score improved significantly from 44.40 ± 4.67 preoperatively to 80.90 ± 5.45 ( p < 0.001). Satisfactory prosthetic positioning parameters were achieved, with a femoral coronal angle of 89.70 ± 6.78°, a tibial coronal angle of 86.80 ± 2.20°, a femoral sagittal angle of 8.40 ± 1.89°, and a tibial sagittal angle of 82.00 ± 2.49°. The SPSI enables accurate localization of femoral prosthesis peg holes, and the femur-first osteotomy workflow optimizes the surgical field and simplifies intraoperative steps. Current preliminary data indicate this novel workflow may serve as a feasible alternative for fixed-bearing UKA, though comparative analysis and long-term survivorship data remain absent.

Journal of Orthopaedic Surgery and Research
The 180th Hospital of PLA (CN)
Natural Science Foundation of Fujian Province
Gender equality
Openalex Percentile: Top 8%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.