Feasibility study of a single-device Phoswich detector for mixed-radiation monitoring: simulation-based evaluation of α/β/γ spectroscopy and practical applicability

Abstract Conventional surface contamination monitoring at radiation facilities and nuclear-medicine settings requires separate detectors for α-, β-, and γ-rays, complicating simultaneous measurement. A three-layer Phoswich scintillation detector (ZnS(Ag)/plastic/GSO(Ce)) enables single-device discrimination via pulse shape discrimination (PSD), but predicting its response is challenging due to complex optical transport and nonlinear energy loss in dead layers. We developed a Geant4 simulation model validated against SRIM (Stopping and Range of Ions in Matter) and ESTAR (Electron STopping powers And Ranges) stopping-power codes to evaluate radiation-type discrimination and nuclide identification feasibility. The simulated photomultiplier tube (PMT) photon-count distributions revealed substantial overlap between β-particles and γ-rays, demonstrating that PSD is essential. Provided that PSD-based classification is achieved (experimentally established for the present configuration), energy resolutions of 3.92–5.24% (α, 3.5–8.0 MeV) and 12.77–17.83% (β, 1.0–3.0 MeV) were obtained, sufficient for identifying α-emitter ( 211 At) and β-emitters ( 90 Sr– 90 Y, 137m Ba). γ-emitters ( 99m Tc, 111 In, 201 Tl, 18 F, 137 Cs) were identified via photopeaks, while higher-energy γ-rays produced Compton continua. L’Hoir asymmetric fitting extracted α and β peak centroids under area-source conditions. This study provides a quantitative foundation for single-device Phoswich detectors in mixed-radiation monitoring across radiation-facility and nuclear-medicine environments.

Authors

Publication Details

Journal
Scientific Reports
Published
2026-09-05
DOI
https://doi.org/10.1038/s41598-026-70074-8
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility study of a single-device Phoswich detector for mixed-radiation monitoring: simulation-based evaluation of α/β/γ spectroscopy and practical applicability

Masayori Ishikawa, Norifumi Abo
Scientific Reports
Radiation Detection and Scintillator Technologies
article

Feasibility study of a single-device Phoswich detector for mixed-radiation monitoring: simulation-based evaluation of α/β/γ spectroscopy and practical applicability

Masayori Ishikawa, Norifumi Abo
article en

Abstract

Abstract Conventional surface contamination monitoring at radiation facilities and nuclear-medicine settings requires separate detectors for α-, β-, and γ-rays, complicating simultaneous measurement. A three-layer Phoswich scintillation detector (ZnS(Ag)/plastic/GSO(Ce)) enables single-device discrimination via pulse shape discrimination (PSD), but predicting its response is challenging due to complex optical transport and nonlinear energy loss in dead layers. We developed a Geant4 simulation model validated against SRIM (Stopping and Range of Ions in Matter) and ESTAR (Electron STopping powers And Ranges) stopping-power codes to evaluate radiation-type discrimination and nuclide identification feasibility. The simulated photomultiplier tube (PMT) photon-count distributions revealed substantial overlap between β-particles and γ-rays, demonstrating that PSD is essential. Provided that PSD-based classification is achieved (experimentally established for the present configuration), energy resolutions of 3.92–5.24% (α, 3.5–8.0 MeV) and 12.77–17.83% (β, 1.0–3.0 MeV) were obtained, sufficient for identifying α-emitter ( 211 At) and β-emitters ( 90 Sr– 90 Y, 137m Ba). γ-emitters ( 99m Tc, 111 In, 201 Tl, 18 F, 137 Cs) were identified via photopeaks, while higher-energy γ-rays produced Compton continua. L’Hoir asymmetric fitting extracted α and β peak centroids under area-source conditions. This study provides a quantitative foundation for single-device Phoswich detectors in mixed-radiation monitoring across radiation-facility and nuclear-medicine environments.

Scientific Reports
Japan Society for the Promotion of Science
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 11%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.