Electrical resistivity of geopolymer concrete: Understanding microstructure and pore solution chemistry to establish transport-based specifications

Surface (AASHTO T 358) and bulk (AASHTO TP 119) electrical resistivity tests are widely recognised as rapid, user-friendly indicators of concrete durability. However, as both methods were developed and validated for Portland cement concrete (OPC), their applicability to geopolymer concrete (GPC) has not been verified. This paper examines how microstructure and pore-solution chemistry jointly influence the electrical resistivity of fly ash (FA)/ground granulated blast-furnace slag (GGBS)-based GPC systems. A total of 60 GPC mixtures with GGBS contents ranging from 15% to 85%, Na 2 O contents from 4.43% to 8.43%, and activator moduli from 0.91 to 1.80 were investigated under both one-part and two-part synthesis routes. All specimens were tested at 28 days under controlled vacuum saturation conditions (ASTM C1202). By identifying the key parameters (precursor chemistry, activator composition, and FA/GGBS ratio) that control resistivity and linking resistivity measurements to durability performance, this study proposes preliminary performance-based durability specifications for chloride resistance in the investigated GPC systems. To directly link resistivity to pore-solution chemistry, the elemental concentrations (Na, Si, K, Al, Ca, Fe, and Mg) of the extracted pore solution were measured via ICP-OES, along with porosity and pore size distribution via mercury intrusion porosimetry and apparent volume of permeable voids. The results demonstrate that lower porosity, reduced extracted pore-solution elemental concentrations, or higher pore-solution resistivity do not necessarily translate into higher overall GPC resistivity, underscoring differences from conventional OPC-based interpretations. For instance, increasing GGBS content reduced pore-solution resistivity while increasing GPC resistivity. However, thermal curing increased both pore-solution and GPC resistivity compared with ambient curing. To avoid misinterpretation, electrical resistivity in GPC must be evaluated by considering both pore-solution chemistry and porosity. The predictive capability of electrical resistivity was evaluated against chloride diffusion coefficients (ASTM C1556), using the adjusted formation factor ( FF a ) assessed as an indicator of transport behaviour in GPC. Both resistivity and FF a showed strong correlations with the apparent diffusion coefficient (R 2 ≈ 0.90), supporting the development of preliminary resistivity- and FF a -based criteria for different AS 3600 exposure classes within the investigated FA/GGBS-based GPC systems. By considering the combined influence of mix design, microstructure, and pore solution chemistry, this study presents a preliminary framework for interpreting resistivity-based durability performance of GPC and contributes toward bridging the gap between laboratory measurements and practical implementation.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2026-09-05
DOI
https://doi.org/10.1016/j.conbuildmat.2026.148062
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical resistivity of geopolymer concrete: Understanding microstructure and pore solution chemistry to establish transport-based specifications

Ailar Hajimohammadi, Stephen J. Foster, Taehwan Kim, Md Ibrahim Mostazid et al.
Construction and Building Materials
Concrete and Cement Materials Research
article

Electrical resistivity of geopolymer concrete: Understanding microstructure and pore solution chemistry to establish transport-based specifications

Ailar Hajimohammadi, Stephen J. Foster, Taehwan Kim, Md Ibrahim Mostazid, Basil Ben, Hossein Asadi
article en

Abstract

Surface (AASHTO T 358) and bulk (AASHTO TP 119) electrical resistivity tests are widely recognised as rapid, user-friendly indicators of concrete durability. However, as both methods were developed and validated for Portland cement concrete (OPC), their applicability to geopolymer concrete (GPC) has not been verified. This paper examines how microstructure and pore-solution chemistry jointly influence the electrical resistivity of fly ash (FA)/ground granulated blast-furnace slag (GGBS)-based GPC systems. A total of 60 GPC mixtures with GGBS contents ranging from 15% to 85%, Na 2 O contents from 4.43% to 8.43%, and activator moduli from 0.91 to 1.80 were investigated under both one-part and two-part synthesis routes. All specimens were tested at 28 days under controlled vacuum saturation conditions (ASTM C1202). By identifying the key parameters (precursor chemistry, activator composition, and FA/GGBS ratio) that control resistivity and linking resistivity measurements to durability performance, this study proposes preliminary performance-based durability specifications for chloride resistance in the investigated GPC systems. To directly link resistivity to pore-solution chemistry, the elemental concentrations (Na, Si, K, Al, Ca, Fe, and Mg) of the extracted pore solution were measured via ICP-OES, along with porosity and pore size distribution via mercury intrusion porosimetry and apparent volume of permeable voids. The results demonstrate that lower porosity, reduced extracted pore-solution elemental concentrations, or higher pore-solution resistivity do not necessarily translate into higher overall GPC resistivity, underscoring differences from conventional OPC-based interpretations. For instance, increasing GGBS content reduced pore-solution resistivity while increasing GPC resistivity. However, thermal curing increased both pore-solution and GPC resistivity compared with ambient curing. To avoid misinterpretation, electrical resistivity in GPC must be evaluated by considering both pore-solution chemistry and porosity. The predictive capability of electrical resistivity was evaluated against chloride diffusion coefficients (ASTM C1556), using the adjusted formation factor ( FF a ) assessed as an indicator of transport behaviour in GPC. Both resistivity and FF a showed strong correlations with the apparent diffusion coefficient (R 2 ≈ 0.90), supporting the development of preliminary resistivity- and FF a -based criteria for different AS 3600 exposure classes within the investigated FA/GGBS-based GPC systems. By considering the combined influence of mix design, microstructure, and pore solution chemistry, this study presents a preliminary framework for interpreting resistivity-based durability performance of GPC and contributes toward bridging the gap between laboratory measurements and practical implementation.

Construction and Building MaterialsVol. 542
UNSW Sydney (AU)
Australian Research Council
Openalex Percentile: Top 16%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.