Addressing Data Imbalance in Operational State Recognition for Photovoltaic and Wind Power Systems via DCGAN-Based Augmentation and 2D-CNN

Accurate state identification is crucial for the safe and efficient operation of renewable energy systems. However, monitoring data from photovoltaic (PV) and wind power systems often suffer from significant class imbalance. This imbalance reduces state recognition accuracy. In this study, we propose one framework to augment fault data and recognize operating states for a combined PV–wind system. The framework first converts signals into images using the Gramian Angular Summation Field (GASF). It then groups samples with K-means clustering. Next, a deep convolutional generative adversarial network (DCGAN) generates additional fault samples for minority classes. Finally, a two-dimensional convolutional neural network (2D-CNN) identifies the operating state. PV and wind time-series signals are first mapped into 2D images via GASF to yield richer spatial-feature representations, and K-means clustering is then used to define operating states in an unsupervised manner and generate the corresponding labels. In PV-only, wind-only, and combined PV–wind scenarios, the baseline 2D-CNN trained on imbalanced datasets achieves recognition accuracies of 95.89%, 57.93%, and 81.94%, respectively. To alleviate class imbalance, DCGAN is employed to synthesize images and construct balanced datasets; the best recognition accuracies in the three scenarios increase to 99.20%, 97.08%, and 97.62%, and the model shows stronger robustness in identifying minority classes. This approach supports both single-source applications and multi-source systems such as large-scale wind–solar bases by providing data and algorithmic foundations for generalized fault-diagnosis models, thereby enabling more reliable, data-driven operational monitoring.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-18
DOI
https://doi.org/10.3390/en19225577
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Addressing Data Imbalance in Operational State Recognition for Photovoltaic and Wind Power Systems via DCGAN-Based Augmentation and 2D-CNN

Yongwen Yang, Qifen Li, Luping Xin, Fanyue Qian et al.
8 links
Energies
Machine Fault Diagnosis Techniques
article

Addressing Data Imbalance in Operational State Recognition for Photovoltaic and Wind Power Systems via DCGAN-Based Augmentation and 2D-CNN

Yongwen Yang, Qifen Li, Luping Xin, Fanyue Qian, Lifei Song, Liting Zhang, Siqi Cheng
article en

Abstract

Accurate state identification is crucial for the safe and efficient operation of renewable energy systems. However, monitoring data from photovoltaic (PV) and wind power systems often suffer from significant class imbalance. This imbalance reduces state recognition accuracy. In this study, we propose one framework to augment fault data and recognize operating states for a combined PV–wind system. The framework first converts signals into images using the Gramian Angular Summation Field (GASF). It then groups samples with K-means clustering. Next, a deep convolutional generative adversarial network (DCGAN) generates additional fault samples for minority classes. Finally, a two-dimensional convolutional neural network (2D-CNN) identifies the operating state. PV and wind time-series signals are first mapped into 2D images via GASF to yield richer spatial-feature representations, and K-means clustering is then used to define operating states in an unsupervised manner and generate the corresponding labels. In PV-only, wind-only, and combined PV–wind scenarios, the baseline 2D-CNN trained on imbalanced datasets achieves recognition accuracies of 95.89%, 57.93%, and 81.94%, respectively. To alleviate class imbalance, DCGAN is employed to synthesize images and construct balanced datasets; the best recognition accuracies in the three scenarios increase to 99.20%, 97.08%, and 97.62%, and the model shows stronger robustness in identifying minority classes. This approach supports both single-source applications and multi-source systems such as large-scale wind–solar bases by providing data and algorithmic foundations for generalized fault-diagnosis models, thereby enabling more reliable, data-driven operational monitoring.

EnergiesVol. 19(22)
Tongji University (CN), Shanghai University of Electric Power (CN)
National Natural Science Foundation of China
Affordable and clean energy, Industry, innovation and infrastructure, Climate action
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon