Spectroscopic Measurement of Radon Concentration in Air Using an α-Ionization Chamber

Radon is a major contributor to natural radiation exposure in humans and requires reliable monitoring of its concentrations in indoor and outdoor environments. This paper presents a pulse-proportional ionization chamber with a working volume of 8 L, developed for direct measurement of low radon concentrations. A double-cylindrical coaxial design enables nearly complete detection of α radiation. A specially developed spectroscopic evaluation method was implemented to separate the 222Rn contribution from the spectral components of the short-lived decay products, 218Po, and 214Po, thereby enabling a more accurate determination of radon activity concentration. Acoustic and vibration interference are effectively suppressed, which enables an energy resolution of approximately 2%. At a radon activity concentration of 50 Bq/m³, measurement uncertainties of less than 5% are achieved after just 30 min of measurement time. These characteristics make the system a powerful instrument for high-resolution radon monitoring in ambient air.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-09-04
DOI
https://doi.org/10.3390/app16178825
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectroscopic Measurement of Radon Concentration in Air Using an α-Ionization Chamber

Ralf Nötzel, Kerstin Weinberg
Applied Sciences
Radioactivity and Radon Measurements
article

Spectroscopic Measurement of Radon Concentration in Air Using an α-Ionization Chamber

Ralf Nötzel, Kerstin Weinberg
article en

Abstract

Radon is a major contributor to natural radiation exposure in humans and requires reliable monitoring of its concentrations in indoor and outdoor environments. This paper presents a pulse-proportional ionization chamber with a working volume of 8 L, developed for direct measurement of low radon concentrations. A double-cylindrical coaxial design enables nearly complete detection of α radiation. A specially developed spectroscopic evaluation method was implemented to separate the 222Rn contribution from the spectral components of the short-lived decay products, 218Po, and 214Po, thereby enabling a more accurate determination of radon activity concentration. Acoustic and vibration interference are effectively suppressed, which enables an energy resolution of approximately 2%. At a radon activity concentration of 50 Bq/m³, measurement uncertainties of less than 5% are achieved after just 30 min of measurement time. These characteristics make the system a powerful instrument for high-resolution radon monitoring in ambient air.

Applied SciencesVol. 16(17)
University of Siegen (DE)
European Commission
Affordable and clean energy
Openalex Percentile: Top 10%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.