Airway leakage due to intratracheal malpositioning of an oesophageal temperature probe in an anaesthetised dog

A 10-year-old, 16.2-kg male neutered Beagle under general anaesthesia developed an airway leak following blind insertion of an oesophageal temperature probe. Before probe placement, anaesthesia was uneventful. Intubation was performed with a high-volume, low-pressure cuffed endotracheal tube. Immediately after probe placement, capnographic morphology transitioned from a normal rectangular waveform to a low-amplitude, triangular trace consistent with airway leakage. Repeated cuff inflation did not resolve the capnographic abnormalities. Reintubation revealed inadvertent tracheal placement of the temperature probe, which had presumably disrupted the cuff seal. Capnography normalised following reintubation and the procedure was completed uneventfully. This case report describes the malpositioning of an oesophageal temperature probe intratracheally, resulting in airway leakage in an anaesthetised dog. Sudden changes in capnographic waveform or a marked reduction in expected temperature following probe insertion should prompt consideration for oesophageal temperature probe malposition.

Authors

Publication Details

Journal
Australian Veterinary Journal
Published
2026-09-04
DOI
https://doi.org/10.1111/avj.70140
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airway leakage due to intratracheal malpositioning of an oesophageal temperature probe in an anaesthetised dog

H. Lehmann, EA Drynan, T Kurniawan
Australian Veterinary Journal
Airway Management and Intubation Techniques
article

Airway leakage due to intratracheal malpositioning of an oesophageal temperature probe in an anaesthetised dog

H. Lehmann, EA Drynan, T Kurniawan
article en

Abstract

A 10-year-old, 16.2-kg male neutered Beagle under general anaesthesia developed an airway leak following blind insertion of an oesophageal temperature probe. Before probe placement, anaesthesia was uneventful. Intubation was performed with a high-volume, low-pressure cuffed endotracheal tube. Immediately after probe placement, capnographic morphology transitioned from a normal rectangular waveform to a low-amplitude, triangular trace consistent with airway leakage. Repeated cuff inflation did not resolve the capnographic abnormalities. Reintubation revealed inadvertent tracheal placement of the temperature probe, which had presumably disrupted the cuff seal. Capnography normalised following reintubation and the procedure was completed uneventfully. This case report describes the malpositioning of an oesophageal temperature probe intratracheally, resulting in airway leakage in an anaesthetised dog. Sudden changes in capnographic waveform or a marked reduction in expected temperature following probe insertion should prompt consideration for oesophageal temperature probe malposition.

Australian Veterinary Journal
Life below water
Openalex Percentile: Top 8%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.