Agreement of four metabolic equations for estimating submaximal cycling oxygen uptake with two portable indirect calorimetry systems in untrained young women
Abstract Background Metabolic prediction equations provide a low-cost means of estimating submaximal cycling oxygen uptake (VO₂), yet equations derived from maximal exercise are often applied to steady-state fixed-load protocols without validation. Portable analysers including the COSMED K5 and CORTEX MetaMax 3B permit field-based VO₂ measurement, but neither is error-free. We assessed agreement between four prediction equations and both devices in untrained young women, partitioning total error into bias-related and residual components. Methods Nineteen untrained young women completed four constant-power cycling stages (30, 40, 50, 60 W). VO₂ was estimated from four equations (one submaximal cycling formula, three maximal-test equations) and measured concurrently with two portable indirect calorimeters. Linear mixed-effects models accounted for repeated within-participant observations. Agreement was evaluated using Lin’s concordance correlation coefficient (CCC), mean absolute percentage error (MAPE) and Bland–Altman analysis with proportional bias testing; 95% confidence intervals came from participant-level cluster bootstrap, with false discovery rate correction. Results Every equation–device combination showed significant negative bias (all P < 0.01), and underprediction worsened at higher intensities. The ACSM submaximal equation with CORTEX MetaMax 3B showed the closest agreement (CCC = 0.69, MAPE = 12.9%, bias = − 1.71 mL·kg⁻¹·min⁻¹), with residual error accounting for 68.5% of total disagreement. The three maximal-test equations paired with COSMED K5 yielded the largest errors, 83–91% of which was bias-related. Even the best combination showed growing underprediction as power increased. Conclusions The ACSM submaximal cycling equation showed the closest relative agreement among the eight tested pairings. Maximal-test equations agreed poorly with device-measured values during low-to-moderate fixed-load cycling. Without a laboratory gold standard, these findings reflect relative cross-device agreement rather than absolute accuracy, and disagreement cannot be attributed solely to equation error. The intensity-dependent bias suggests that a universal correction factor would be inadequate under the tested conditions. Any correction approach would require population- and device-specific external validation before clinical use.
Authors
- Shenglong Le (ORCID: https://orcid.org/0000-0003-0925-9660)
- Feng Gao (ORCID: https://orcid.org/0000-0003-3017-4434)
- Sanghee Yang
- Yuxin Xiao
- Zhi Li (ORCID: https://orcid.org/0000-0001-5503-1734)
- Fei Liu (ORCID: https://orcid.org/0000-0003-2811-9479)
- Wenjun Yu (ORCID: https://orcid.org/0009-0009-5570-7410)
- Yongfu Liu
- Di Liu (ORCID: https://orcid.org/0000-0003-3693-2726)
- Song YUAN
Institutions
- Hubei University of Medicine (CN)
- Shanghai Jiao Tong University (CN)
- Taihe Hospital (CN)
- Wuhan Sports University (CN)
Publication Details
- Journal
- BMC Sports Science Medicine and Rehabilitation
- Published
- 2026-09-04
- DOI
- https://doi.org/10.1186/s13102-026-02046-4
- Primary Topic
- Cardiovascular and exercise physiology
- Type
- article
- Field-Weighted Citation Impact
- 0.00