EXPRESS: ICP-MS Analysis of Pipe Tobacco Using Calibration by Proxy

Calibration by Proxy (CbPx) is applied to the inductively coupled plasma mass spectrometry analysis of seven commercial pipe tobacco samples. Five proxy elements are employed to construct a single calibration curve that applies to every analyte in the sample. Both the preparation of the calibration curve and the multielement analysis of each sample is performed from the analysis of just two solutions. The analysis of a standard reference material (tomato leaves) demonstrates excellent recoveries for 12 test elements, ranging from 77% (Ni) to 104% (Cu), with relative standard deviations averaging 6.6%. Detection limits are in the ppb range (µg analyte per kg leaf). Pipe tobacco samples containing between 0.04 and 700 mg analyte per kg leaf are analyzed for Al, As, Ba, Cd, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn.

Authors

Publication Details

Journal
Applied Spectroscopy
Published
2026-09-04
DOI
https://doi.org/10.1177/00037028261486540
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPRESS: ICP-MS Analysis of Pipe Tobacco Using Calibration by Proxy

Willis B. Jones, Beatriz M. Fontoura, Bradley T. Jones, Hanieh Helli
Applied Spectroscopy
Analytical chemistry methods development
article

EXPRESS: ICP-MS Analysis of Pipe Tobacco Using Calibration by Proxy

Willis B. Jones, Beatriz M. Fontoura, Bradley T. Jones, Hanieh Helli
article en

Abstract

Calibration by Proxy (CbPx) is applied to the inductively coupled plasma mass spectrometry analysis of seven commercial pipe tobacco samples. Five proxy elements are employed to construct a single calibration curve that applies to every analyte in the sample. Both the preparation of the calibration curve and the multielement analysis of each sample is performed from the analysis of just two solutions. The analysis of a standard reference material (tomato leaves) demonstrates excellent recoveries for 12 test elements, ranging from 77% (Ni) to 104% (Cu), with relative standard deviations averaging 6.6%. Detection limits are in the ppb range (µg analyte per kg leaf). Pipe tobacco samples containing between 0.04 and 700 mg analyte per kg leaf are analyzed for Al, As, Ba, Cd, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn.

Applied Spectroscopy
Good health and well-being
Openalex Percentile: Top 15%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.