Total dose effects on operational amplifiers with MOSFET input
In this paper, we explore the total ionizing dose effects on the offset voltage of the commercial off-the-shelf high-voltage MOSFET-input operational amplifier CA3140 for use in dosimetry applications. The devices were irradiated under different biasing conditions using a 60Co γ-ray source from a radiotherapy unit. Both experimental results and a physics-based analytical model show that the radiation response of the operational amplifier is governed by the radiation-induced degradation of the MOSFET input pair. Estimates from measurements give a sensitivity of 2.5 mV/cGy(SiO2) and a noise equivalent dose of 0.9 cGy(SiO2).
Authors
- A. Faigón
- S. Carbonetto
- L. Sambuco Salomone
- M. Garcia-Inza
- E. Redin
- G. Salaya
Institutions
- National Technological University (AR)
- Universidad de Buenos Aires (AR)
- Centro Científico Tecnológico - Tucumán (AR)
- Universidad Nacional Tecnológica (DO)
Publication Details
- Journal
- Radiation effects and defects in solids
- Published
- 2026-09-04
- DOI
- https://doi.org/10.1080/10420150.2026.2721518
- Primary Topic
- Radiation Effects in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Universidad de Buenos Aires
- Agencia Nacional de Promoción de la Investigación, el Desarrollo Tecnológico y la Innovación