Closer matching between flow diverter diameter and parent artery diameter is associated with improved aneurysm occlusion

Background: Selecting the flow diverter (FD) size is key to treatment outcomes in unruptured intracranial aneurysms. However, the impact of differences between the nominal and actual deployed device sizes on aneurysm occlusion is not fully understood. This study retrospectively evaluated the relationship between FD size and aneurysm occlusion. Methods: We retrospectively analyzed 54 patients with unruptured intracranial aneurysms who underwent FD placement at our institution from March 2023 to March 2025, where both length (Length_D) and diameter (Size_D) discrepancies were evaluated. Devices used were a Flow Redirection Endoluminal Device in 31 cases and a Pipeline Embolization Device in 23 cases. Length_D is the difference between the nominal device length and actual deployed length, while Size_D is the difference between the nominal device diameter and actual deployed diameter. The primary endpoint was aneurysm occlusion at 6 months, assessed using the O’Kelly–Marotta (OKM) scale. Adequate occlusion was defined as OKM grades C–D and incomplete occlusion as OKM grades A–B. Patients were divided into adequate and incomplete occlusion groups, and Length_D and Size_D were compared. Results: Adequate occlusion was achieved in 68.5% of patients. The mean Length_D was 2.9 ± 3.9 mm in the adequate occlusion group and 6.7 ± 5.1 mm in the incomplete occlusion group, with a significantly greater value in the incomplete occlusion group. Conclusion: Greater FD elongation post-deployment may be linked to lower aneurysm occlusion rates at 6 months. Choosing an FD size that matches the parent vessel diameter is crucial for optimal occlusion.

Authors

Institutions

Publication Details

Journal
Surgical Neurology International
Published
2026-09-04
DOI
https://doi.org/10.25259/sni_564_2026
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Closer matching between flow diverter diameter and parent artery diameter is associated with improved aneurysm occlusion

Hiroshi Aikawa, Masahiro Yasaka, Takashi Fujii, Hidenori Oishi et al.
Surgical Neurology International
Intracranial Aneurysms: Treatment and Complications
article

Closer matching between flow diverter diameter and parent artery diameter is associated with improved aneurysm occlusion

Hiroshi Aikawa, Masahiro Yasaka, Takashi Fujii, Hidenori Oishi, Yoshinori Go, Kousei Maruyama, Yoshimasa Fukui, Kiyoshi Kazekawa, Kousuke Takigawa, Shuta Maehara, Kunihiro Matsumoto
article en

Abstract

Background: Selecting the flow diverter (FD) size is key to treatment outcomes in unruptured intracranial aneurysms. However, the impact of differences between the nominal and actual deployed device sizes on aneurysm occlusion is not fully understood. This study retrospectively evaluated the relationship between FD size and aneurysm occlusion. Methods: We retrospectively analyzed 54 patients with unruptured intracranial aneurysms who underwent FD placement at our institution from March 2023 to March 2025, where both length (Length_D) and diameter (Size_D) discrepancies were evaluated. Devices used were a Flow Redirection Endoluminal Device in 31 cases and a Pipeline Embolization Device in 23 cases. Length_D is the difference between the nominal device length and actual deployed length, while Size_D is the difference between the nominal device diameter and actual deployed diameter. The primary endpoint was aneurysm occlusion at 6 months, assessed using the O’Kelly–Marotta (OKM) scale. Adequate occlusion was defined as OKM grades C–D and incomplete occlusion as OKM grades A–B. Patients were divided into adequate and incomplete occlusion groups, and Length_D and Size_D were compared. Results: Adequate occlusion was achieved in 68.5% of patients. The mean Length_D was 2.9 ± 3.9 mm in the adequate occlusion group and 6.7 ± 5.1 mm in the incomplete occlusion group, with a significantly greater value in the incomplete occlusion group. Conclusion: Greater FD elongation post-deployment may be linked to lower aneurysm occlusion rates at 6 months. Choosing an FD size that matches the parent vessel diameter is crucial for optimal occlusion.

Surgical Neurology InternationalVol. 17
Fukuoka Hospital (JP), Ohkawara Neurosurgical Hospital (JP), South Osaka Neurosurgical Hospital (JP)
Good health and well-being
Openalex Percentile: Top 11%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.