Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants

Background 316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inadequate surface interactions with biological tissues. Surface modification using Ti-based physical vapor deposition (PVD) coatings has emerged as a promising strategy to enhance the corrosion resistance and durability of implant materials. Objective This study aimed to investigate the effect of Ti-based PVD coatings, namely TiCoCr, TiN, and TiO 2 , on the corrosion behavior of 316L SS under simulated physiological conditions. Methods TiCoCr, TiN, and TiO 2 coatings were deposited onto 316L SS substrates using the PVD technique. The corrosion performance of the coated and uncoated samples was evaluated in phosphate-buffered saline (PBS), Hanks’ solution, and Ringer's solution at 37 °C. Electrochemical corrosion parameters, including corrosion potential and corrosion current density, were analyzed to assess the effectiveness of the coatings. Results All Ti-based coatings improved the corrosion resistance of 316L SS compared with the uncoated substrate. Among the investigated coatings, the TiCoCr coating deposited for 90 min exhibited the best corrosion performance. In Ringer's solution, the coating showed a corrosion potential of −0.0504 V and a corrosion current density of 4.74 × 10 −6 A/cm 2 . In Hanks’ solution, the same coating demonstrated a corrosion potential of −0.1815 V and a corrosion current density of 5.0537 × 10 −6 A/cm 2 . The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer. Conclusion The TiCoCr, TiN, and TiO 2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments. Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.

Authors

Publication Details

Journal
Bio-Medical Materials and Engineering
Published
2026-09-04
DOI
https://doi.org/10.1177/09592989261485537
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants

M Shunmuga Priyan, G Godwin
Bio-Medical Materials and Engineering
Titanium Alloys Microstructure and Properties
article

Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants

M Shunmuga Priyan, G Godwin
article en

Abstract

Background 316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inadequate surface interactions with biological tissues. Surface modification using Ti-based physical vapor deposition (PVD) coatings has emerged as a promising strategy to enhance the corrosion resistance and durability of implant materials. Objective This study aimed to investigate the effect of Ti-based PVD coatings, namely TiCoCr, TiN, and TiO 2 , on the corrosion behavior of 316L SS under simulated physiological conditions. Methods TiCoCr, TiN, and TiO 2 coatings were deposited onto 316L SS substrates using the PVD technique. The corrosion performance of the coated and uncoated samples was evaluated in phosphate-buffered saline (PBS), Hanks’ solution, and Ringer's solution at 37 °C. Electrochemical corrosion parameters, including corrosion potential and corrosion current density, were analyzed to assess the effectiveness of the coatings. Results All Ti-based coatings improved the corrosion resistance of 316L SS compared with the uncoated substrate. Among the investigated coatings, the TiCoCr coating deposited for 90 min exhibited the best corrosion performance. In Ringer's solution, the coating showed a corrosion potential of −0.0504 V and a corrosion current density of 4.74 × 10 −6 A/cm 2 . In Hanks’ solution, the same coating demonstrated a corrosion potential of −0.1815 V and a corrosion current density of 5.0537 × 10 −6 A/cm 2 . The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer. Conclusion The TiCoCr, TiN, and TiO 2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments. Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.

Bio-Medical Materials and Engineering
Openalex Percentile: Top 24%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.