The Impact of Countersinking Headless Compression Screws on Fracture Compression

Abstract Scaphoid fractures are commonly fixated with headless compression screws. These devices generate intrinsic compression that is dependent on the bone-screw interface at the proximal and distal fragments as well as depth of insertion. To minimize the risk of prominent hardware, screws are countersunk beneath chondral surfaces, but the biomechanical implications of this practice have not been explored. The purpose of this study is to characterize fracture compression with and without countersinking in three fracture arrangements for a fully threaded headless compression screw. Tests were performed on three Sawbones models and two insertion techniques. The fracture models representing proximal, waist, and distal fractures were composed of a top foam sheet of varying thickness (10, 14, and 18 mm) and a bottom sheet (25 mm) spaced 2 mm apart. Both insertion techniques utilized a 30 mm fully threaded screw inserted with a force of 35 N at 30 rpm. Flush insertion concluded when the screw head was level with the top block, and countersunk insertion was concluded when the screw head was 2 mm beneath the top block surface. This process was completed five times in each configuration. Comparisons between groups were performed using a Wilcoxon Rank-Sum test with significance set at p = 0.05. Fracture compression was similar when countersinking screws in models of proximal or waist fractures but dropped significantly in the model of distal fracture. Driving torque was consistent regardless of screw position or model. There is a higher risk of compression loss when countersinking headless compression screws if the distal fragment is small. When using variable pitch headless compression screws, it is advisable to pick a trajectory where the smaller fragment is entered first to minimize the risk of fixation loss during countersinking.

Authors

Institutions

Publication Details

Journal
Journal of Wrist Surgery
Published
2026-09-04
DOI
https://doi.org/10.1055/a-2940-2030
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Countersinking Headless Compression Screws on Fracture Compression

Eric R. Wagner, Spencer B. Chambers, Nina Suh, James Thompson et al.
Journal of Wrist Surgery
Orthopedic Surgery and Rehabilitation
article

The Impact of Countersinking Headless Compression Screws on Fracture Compression

Eric R. Wagner, Spencer B. Chambers, Nina Suh, James Thompson, Michael B. Gottschalk
article en

Abstract

Abstract Scaphoid fractures are commonly fixated with headless compression screws. These devices generate intrinsic compression that is dependent on the bone-screw interface at the proximal and distal fragments as well as depth of insertion. To minimize the risk of prominent hardware, screws are countersunk beneath chondral surfaces, but the biomechanical implications of this practice have not been explored. The purpose of this study is to characterize fracture compression with and without countersinking in three fracture arrangements for a fully threaded headless compression screw. Tests were performed on three Sawbones models and two insertion techniques. The fracture models representing proximal, waist, and distal fractures were composed of a top foam sheet of varying thickness (10, 14, and 18 mm) and a bottom sheet (25 mm) spaced 2 mm apart. Both insertion techniques utilized a 30 mm fully threaded screw inserted with a force of 35 N at 30 rpm. Flush insertion concluded when the screw head was level with the top block, and countersunk insertion was concluded when the screw head was 2 mm beneath the top block surface. This process was completed five times in each configuration. Comparisons between groups were performed using a Wilcoxon Rank-Sum test with significance set at p = 0.05. Fracture compression was similar when countersinking screws in models of proximal or waist fractures but dropped significantly in the model of distal fracture. Driving torque was consistent regardless of screw position or model. There is a higher risk of compression loss when countersinking headless compression screws if the distal fragment is small. When using variable pitch headless compression screws, it is advisable to pick a trajectory where the smaller fragment is entered first to minimize the risk of fixation loss during countersinking.

Journal of Wrist Surgery
Emory University (US), St. Joseph's Hospital (CA)
Openalex Percentile: Top 8%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.