MergeNeXt: a hybrid CNN–transformer model for retinal OCT image classification

Abstract Retinal disease recognition is a critical component of computer-aided diagnosis (CAD). Despite advancements, existing models often struggle to capture both fine-grained local details and complex global relationships in optical coherence tomography (OCT) images. This study aims to develop a high-precision deep learning architecture to improve automated classification accuracy for retinal lesions. This study proposes MergeNeXt, an innovative hybrid model that integrates the strengths of convolutional neural networks (CNNs) and Transformers. The architecture leverages two key components: ConvMerge Block (CMB), which uses a parallel branch structure to independently model spatial and channel features, and Adaptive Double-Channel Attention (ADCA), which employs a dual-pooling strategy to adaptively adjust features. The model was evaluated on retinal OCT datasets and compared against state-of-the-art architectures, including ConvNeXt and RepViT. MergeNeXt achieved an accuracy of 99.58%, a precision of 99.58%, a recall of 99.56%, and an F1 score of 99.57% on the institutional dataset. Five-fold cross-validation yielded an average accuracy of 99.25 ± 0.34%, while evaluation on the public OCT-C8 dataset achieved an accuracy of 98.29%. MergeNeXt contained 27.57 M parameters and required 6.6 ms per image under the reported hardware configuration. It also achieved the highest point estimates across the reported classification metrics among the evaluated models. These findings support the effectiveness, stability, architecture-level cross-dataset generalizability, and computational efficiency of MergeNeXt for retinal OCT image classification. However, prospective and task-matched multicenter and multi-device validation remains necessary before its clinical utility can be established.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-09-04
DOI
https://doi.org/10.1038/s41598-026-70044-0
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MergeNeXt: a hybrid CNN–transformer model for retinal OCT image classification

Ye Yuan, Yuqian Fan, Xiaopeng Li, Jing Liu et al.
Scientific Reports
Retinal Imaging and Analysis
article

MergeNeXt: a hybrid CNN–transformer model for retinal OCT image classification

Ye Yuan, Yuqian Fan, Xiaopeng Li, Jing Liu, Dong Liu, Xiaoxiao Ma, Junjie Jiao, Shaoyi Xue, Zixuan Cao, Zhengze Li, Kun Chang
article en

Abstract

Abstract Retinal disease recognition is a critical component of computer-aided diagnosis (CAD). Despite advancements, existing models often struggle to capture both fine-grained local details and complex global relationships in optical coherence tomography (OCT) images. This study aims to develop a high-precision deep learning architecture to improve automated classification accuracy for retinal lesions. This study proposes MergeNeXt, an innovative hybrid model that integrates the strengths of convolutional neural networks (CNNs) and Transformers. The architecture leverages two key components: ConvMerge Block (CMB), which uses a parallel branch structure to independently model spatial and channel features, and Adaptive Double-Channel Attention (ADCA), which employs a dual-pooling strategy to adaptively adjust features. The model was evaluated on retinal OCT datasets and compared against state-of-the-art architectures, including ConvNeXt and RepViT. MergeNeXt achieved an accuracy of 99.58%, a precision of 99.58%, a recall of 99.56%, and an F1 score of 99.57% on the institutional dataset. Five-fold cross-validation yielded an average accuracy of 99.25 ± 0.34%, while evaluation on the public OCT-C8 dataset achieved an accuracy of 98.29%. MergeNeXt contained 27.57 M parameters and required 6.6 ms per image under the reported hardware configuration. It also achieved the highest point estimates across the reported classification metrics among the evaluated models. These findings support the effectiveness, stability, architecture-level cross-dataset generalizability, and computational efficiency of MergeNeXt for retinal OCT image classification. However, prospective and task-matched multicenter and multi-device validation remains necessary before its clinical utility can be established.

Scientific Reports
Henan Institute of Science and Technology (CN), Henan Medical University (CN)
Openalex Percentile: Top 11%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.