From load-bearing to load-sharing: contact-driven transitions in locked plate constructs

Locked plate osteosynthesis functions as an internal fixator, yet load-induced plate-bone and fragment-fragment contacts - key transitions from load-bearing to load-sharing - remain poorly characterized. This study quantified their effects on construct stiffness, plate strain, and interfragmentary motion under axial loading. Twenty-seven configurations were tested using epoxy-glass surrogate bone fixed with titanium LCP plates, varying fracture gap (3-9 mm), working length (49-121 mm), and plate-bone distance (0-3 mm). Digital image correlation measured strain and motion. Contact events were identified manually from characteristic transitions in the force-displacement response, supported by corresponding changes in plate-surface strain progression. Geometric parameters dominated initial stiffness (125-442 N/mm), decreasing with plate elevation and working length in elevated setups. Within the investigated load range up to 600 N, 16/27 configurations showed non-linear transitions associated with contact events: fragment-fragment contact caused pronounced stiffness increases and strain stagnation at the fracture gap, whereas plate-bone contact was associated with local plate-surface strain stagnation at the location overlying the contact while strain at the fracture gap continued to increase. Interfragmentary motion stagnated after contact, confirming contact-dependent shifts in load transfer. Response surface regression explained 81.9% of the variance in initial stiffness and 89.6% of the variance in axial interfragmentary motion, identifying outcome-specific associations with geometric parameters and selected interaction terms. In conclusion, load-dependent contact events were associated with distinct transitions in construct stiffness, plate-surface strain progression, and interfragmentary motion, complementing the observed associations between geometric parameters and initial mechanical behavior.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-09-04
DOI
https://doi.org/10.1007/s00402-026-06494-y
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From load-bearing to load-sharing: contact-driven transitions in locked plate constructs

Marianne Hollensteiner, Markus Greinwald, Mischa Mühling, Peter Augat et al.
Archives of Orthopaedic and Trauma Surgery
Bone health and osteoporosis research
article

From load-bearing to load-sharing: contact-driven transitions in locked plate constructs

Marianne Hollensteiner, Markus Greinwald, Mischa Mühling, Peter Augat, Martina Schindler, Dirk Baumeister
article en

Abstract

Locked plate osteosynthesis functions as an internal fixator, yet load-induced plate-bone and fragment-fragment contacts - key transitions from load-bearing to load-sharing - remain poorly characterized. This study quantified their effects on construct stiffness, plate strain, and interfragmentary motion under axial loading. Twenty-seven configurations were tested using epoxy-glass surrogate bone fixed with titanium LCP plates, varying fracture gap (3-9 mm), working length (49-121 mm), and plate-bone distance (0-3 mm). Digital image correlation measured strain and motion. Contact events were identified manually from characteristic transitions in the force-displacement response, supported by corresponding changes in plate-surface strain progression. Geometric parameters dominated initial stiffness (125-442 N/mm), decreasing with plate elevation and working length in elevated setups. Within the investigated load range up to 600 N, 16/27 configurations showed non-linear transitions associated with contact events: fragment-fragment contact caused pronounced stiffness increases and strain stagnation at the fracture gap, whereas plate-bone contact was associated with local plate-surface strain stagnation at the location overlying the contact while strain at the fracture gap continued to increase. Interfragmentary motion stagnated after contact, confirming contact-dependent shifts in load transfer. Response surface regression explained 81.9% of the variance in initial stiffness and 89.6% of the variance in axial interfragmentary motion, identifying outcome-specific associations with geometric parameters and selected interaction terms. In conclusion, load-dependent contact events were associated with distinct transitions in construct stiffness, plate-surface strain progression, and interfragmentary motion, complementing the observed associations between geometric parameters and initial mechanical behavior.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
University of Stuttgart (DE), Paracelsus Medical University (AT), Berufsgenossenschaftliche Unfallklinik Murnau (DE)
Paracelsus Medizinische Privatuniversität
Sustainable cities and communities
Openalex Percentile: Top 9%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.