Accuracy Verification and Correction of a Depth-Camera-Based Digital Measurement System for Pelvic Balance Assessment in the Trendelenburg Test

This study proposes a markerless, single-camera depth-sensing system for digitally quantifying pelvic-balance ability in the Trendelenburg test, and verifies its accuracy and reliability against a marker-based motion capture (MC) reference and manual measurement (MM) in 16 healthy adults. A paired-samples t-test confirmed that the pre-correction bias between MC and DC was significantly different from zero (p < 0.001), whereas the post-correction bias between MC and the corrected DC (cDC) was not (p = 0.791; LOSO p = 0.771), directly confirming that a correction coefficient (a = 89.42%) derived from this systematic bias successfully removed it: Bland–Altman analysis showed that the mean bias (−5.11 mm) was reduced to near zero after correction (0.18 mm), and Lin’s concordance correlation coefficient (CCC) improved correspondingly from 0.944 to 0.981. These findings were consistent with intraclass correlation coefficient (ICC) analysis, which showed excellent consistency (0.980) and absolute agreement (0.946) with MC even before correction, further improving to 0.982 after correction. All improvements were confirmed using Leave-One-Subject-Out (LOSO) cross-validation (CCC = 0.980; absolute-agreement ICC = 0.981; bias = 0.21 mm), indicating that they are not an artifact of evaluating the correction on the same data used to derive it. By contrast, MM showed poor reliability and agreement with MC (CCC = 0.258; ICC = 0.264–0.440), underscoring the limitations of visual, examiner-based assessment. These findings indicate that the proposed single-camera depth-sensing system offers a convenient, markerless alternative to marker-based motion capture, with accuracy and reliability suitable for practical deployment, and that the verification–correction methodology provides a generalizable approach for improving the accuracy of similar low-cost digital measurement systems.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-09-04
DOI
https://doi.org/10.3390/electronics15173988
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Verification and Correction of a Depth-Camera-Based Digital Measurement System for Pelvic Balance Assessment in the Trendelenburg Test

Kwangtae Jung, Jonghyun Kim, Changgi Lee
Electronics
Balance, Gait, and Falls Prevention
article

Accuracy Verification and Correction of a Depth-Camera-Based Digital Measurement System for Pelvic Balance Assessment in the Trendelenburg Test

Kwangtae Jung, Jonghyun Kim, Changgi Lee
article en

Abstract

This study proposes a markerless, single-camera depth-sensing system for digitally quantifying pelvic-balance ability in the Trendelenburg test, and verifies its accuracy and reliability against a marker-based motion capture (MC) reference and manual measurement (MM) in 16 healthy adults. A paired-samples t-test confirmed that the pre-correction bias between MC and DC was significantly different from zero (p < 0.001), whereas the post-correction bias between MC and the corrected DC (cDC) was not (p = 0.791; LOSO p = 0.771), directly confirming that a correction coefficient (a = 89.42%) derived from this systematic bias successfully removed it: Bland–Altman analysis showed that the mean bias (−5.11 mm) was reduced to near zero after correction (0.18 mm), and Lin’s concordance correlation coefficient (CCC) improved correspondingly from 0.944 to 0.981. These findings were consistent with intraclass correlation coefficient (ICC) analysis, which showed excellent consistency (0.980) and absolute agreement (0.946) with MC even before correction, further improving to 0.982 after correction. All improvements were confirmed using Leave-One-Subject-Out (LOSO) cross-validation (CCC = 0.980; absolute-agreement ICC = 0.981; bias = 0.21 mm), indicating that they are not an artifact of evaluating the correction on the same data used to derive it. By contrast, MM showed poor reliability and agreement with MC (CCC = 0.258; ICC = 0.264–0.440), underscoring the limitations of visual, examiner-based assessment. These findings indicate that the proposed single-camera depth-sensing system offers a convenient, markerless alternative to marker-based motion capture, with accuracy and reliability suitable for practical deployment, and that the verification–correction methodology provides a generalizable approach for improving the accuracy of similar low-cost digital measurement systems.

ElectronicsVol. 15(17)
Korea University of Technology and Education (KR), Chung-Ang University (KR), Korea Institute of Industrial Technology (KR)
Rural Development Administration
Openalex Percentile: Top 5%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.