Calibrating artificial intelligence against human expertise using femoral nerve segmentation on ultrasound: a consensus framework

INTRODUCTION: Meaningful validation of artificial intelligence for medical image interpretation requires comparison against human expert performance, yet multi-rater frameworks establishing such comparisons remain uncommon. METHODS: We developed and applied a consensus framework using nine clinicians who independently segmented the femoral nerve on 100 ultrasound images, yielding 900 annotations and a combined consensus standard established by majority voting. We then evaluated an academic deep learning model against this consensus and individual human performance. RESULTS: The artificial intelligence model achieved a median (IQR [range]) Dice coefficient of 0.72 (0.56-0.84 [0.00-0.91]) against combined consensus. Sensitivity was 0.94 (0.88-0.97 [0.33-1.00]) and precision 0.60 (0.44-0.76 [0.00-0.89]). Individual human Dice scores ranged from 0.32 to 0.73 (median 0.60). The artificial intelligence model matched median human performance and outperformed five of nine annotators (31%-125% relative improvement), with the greatest benefit for the lowest-performing practitioners. Leave-one-annotator-out analysis confirmed consensus stability (median (IQR [range]) artificial intelligence Dice 0.749 (0.745-0.752 [0.742-0.769])). Inter-rater reliability was moderate overall (Fleiss's κ 0.54, p < 0.001). DISCUSSION: The sensitivity and precision profile of the artificial intelligence model indicated reliable nerve detection with over-segmentation that remained clinically interpretable. The moderate inter-rater reliability is consistent with the inherent subjectivity of nerve delineation on ultrasound. The circularity inherent in evaluating annotators against a consensus they helped define limits direct comparison of artificial intelligence and human scores. A Dice score of 0.72 represents the upper range of human expert performance rather than moderate accuracy. The framework methodology is independent of the specific artificial intelligence system evaluated and offers a transferable approach for calibrating artificial intelligence performance in clinical imaging where no single correct interpretation exists.

Authors

Institutions

Publication Details

Journal
Anaesthesia
Published
2026-09-01
DOI
https://doi.org/10.1111/anae.70364
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrating artificial intelligence against human expertise using femoral nerve segmentation on ultrasound: a consensus framework

Annelie Augustinsson, Johan Berggreen, Tomas Jansson, Sebastian Möller et al.
Anaesthesia
Artificial Intelligence in Healthcare and Education
article

Calibrating artificial intelligence against human expertise using femoral nerve segmentation on ultrasound: a consensus framework

Annelie Augustinsson, Johan Berggreen, Tomas Jansson, Sebastian Möller, Pether Jildenstål, Anders Johansson
article en

Abstract

INTRODUCTION: Meaningful validation of artificial intelligence for medical image interpretation requires comparison against human expert performance, yet multi-rater frameworks establishing such comparisons remain uncommon. METHODS: We developed and applied a consensus framework using nine clinicians who independently segmented the femoral nerve on 100 ultrasound images, yielding 900 annotations and a combined consensus standard established by majority voting. We then evaluated an academic deep learning model against this consensus and individual human performance. RESULTS: The artificial intelligence model achieved a median (IQR [range]) Dice coefficient of 0.72 (0.56-0.84 [0.00-0.91]) against combined consensus. Sensitivity was 0.94 (0.88-0.97 [0.33-1.00]) and precision 0.60 (0.44-0.76 [0.00-0.89]). Individual human Dice scores ranged from 0.32 to 0.73 (median 0.60). The artificial intelligence model matched median human performance and outperformed five of nine annotators (31%-125% relative improvement), with the greatest benefit for the lowest-performing practitioners. Leave-one-annotator-out analysis confirmed consensus stability (median (IQR [range]) artificial intelligence Dice 0.749 (0.745-0.752 [0.742-0.769])). Inter-rater reliability was moderate overall (Fleiss's κ 0.54, p < 0.001). DISCUSSION: The sensitivity and precision profile of the artificial intelligence model indicated reliable nerve detection with over-segmentation that remained clinically interpretable. The moderate inter-rater reliability is consistent with the inherent subjectivity of nerve delineation on ultrasound. The circularity inherent in evaluating annotators against a consensus they helped define limits direct comparison of artificial intelligence and human scores. A Dice score of 0.72 represents the upper range of human expert performance rather than moderate accuracy. The framework methodology is independent of the specific artificial intelligence system evaluated and offers a transferable approach for calibrating artificial intelligence performance in clinical imaging where no single correct interpretation exists.

Anaesthesia
Lund University (SE), Sahlgrenska University Hospital (SE), Nord University (NO), Skåne University Hospital (SE), Region Skåne (SE)
Gender equality
Openalex Percentile: Top 14%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.