Active power-frequency oscillation suppression strategy for parallel VSG system based on fractional-order control scheme

Since most distributed power sources in microgrids lack the necessary inertia, the frequency stability of the system deteriorates. By emulating the dynamic characteristics of traditional synchronous generators, virtual synchronous generator (VSG) technology provides essential inertia support for power systems, emerging as an effective solution. However, while providing essential inertia and damping, VSGs inevitably induce active power oscillations, a problem that is critically exacerbated when multiple VSGs operate in parallel. To address this issue, this paper proposes an active power-frequency oscillation suppression strategy based on a fractional-order control scheme for the parallel VSG system. By incorporating two fractional-order feedback paths into the VSG active-power control loop, the proposed strategy provides additional degrees of freedom for shaping the active-power and frequency responses. Consequently, the proposed strategy effectively attenuates active-power and frequency oscillations in the parallel VSG system. Subsequently, the closed-loop stability of the parallel VSG system under the proposed fractional-order strategy is established using a Lyapunov energy function. Finally, hardware experiments on a two-unit parallel VSG platform show that, under a resistive-load disturbance, the proposed strategy reduces the maximum active-power overshoot from 9.4 % to 2.6 % and shortens the settling times of the active-power and frequency responses from approximately 0.50 s to 0.21 s, relative to traditional VSG control. This corresponds to an approximately 58 % reduction in settling time, while the desired 2:1 steady-state active-power-sharing ratio is maintained. The improvement in active-power–frequency dynamics is also retained under inductive-load and nonlinear-load disturbances.

Authors

Institutions

Publication Details

Journal
Engineering Science and Technology an International Journal
Published
2026-09-01
DOI
https://doi.org/10.1016/j.jestch.2026.102517
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active power-frequency oscillation suppression strategy for parallel VSG system based on fractional-order control scheme

Lei Zhang, Liansong Xiong, Rongliang Shi, Yu Zhang et al.
Engineering Science and Technology an International Journal
Frequency Control in Power Systems
article

Active power-frequency oscillation suppression strategy for parallel VSG system based on fractional-order control scheme

Lei Zhang, Liansong Xiong, Rongliang Shi, Yu Zhang, Dong Li
article en

Abstract

Since most distributed power sources in microgrids lack the necessary inertia, the frequency stability of the system deteriorates. By emulating the dynamic characteristics of traditional synchronous generators, virtual synchronous generator (VSG) technology provides essential inertia support for power systems, emerging as an effective solution. However, while providing essential inertia and damping, VSGs inevitably induce active power oscillations, a problem that is critically exacerbated when multiple VSGs operate in parallel. To address this issue, this paper proposes an active power-frequency oscillation suppression strategy based on a fractional-order control scheme for the parallel VSG system. By incorporating two fractional-order feedback paths into the VSG active-power control loop, the proposed strategy provides additional degrees of freedom for shaping the active-power and frequency responses. Consequently, the proposed strategy effectively attenuates active-power and frequency oscillations in the parallel VSG system. Subsequently, the closed-loop stability of the parallel VSG system under the proposed fractional-order strategy is established using a Lyapunov energy function. Finally, hardware experiments on a two-unit parallel VSG platform show that, under a resistive-load disturbance, the proposed strategy reduces the maximum active-power overshoot from 9.4 % to 2.6 % and shortens the settling times of the active-power and frequency responses from approximately 0.50 s to 0.21 s, relative to traditional VSG control. This corresponds to an approximately 58 % reduction in settling time, while the desired 2:1 steady-state active-power-sharing ratio is maintained. The improvement in active-power–frequency dynamics is also retained under inductive-load and nonlinear-load disturbances.

Engineering Science and Technology an International JournalVol. 82
Electric Power University (VN), Guilin University of Technology (CN), Guilin University of Electronic Technology (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangxi Province
Affordable and clean energy
Openalex Percentile: Top 20%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.