Impact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial

OBJECTIVE: To determine if intraoperative inspection of patient-specific 3D-printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI). METHODS: This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra-operative inspection of a 3D-printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg-TLX) and analyzed with linear mixed-effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel-questionnaire) and prediction of intraoperative challenges. RESULTS: Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue (p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental (p = 0.01) and physical fatigue (p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity (p = 0.02) offset by higher physical fatigue (p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries. CONCLUSION: The clinical impact of intraoperative 3D-printed models during CI is modulated by surgical experience. For attendings, models act as high-fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training. LEVEL OF EVIDENCE: Level II.

Authors

Institutions

Publication Details

Journal
The Laryngoscope
Published
2026-09-01
DOI
https://doi.org/10.1002/lary.70887
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial

Obinna I. Nwosu, Alicia M. Quesnel, Adam Omari, Steven A.W. Andersen
The Laryngoscope
Surgical Simulation and Training
article

Impact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial

Obinna I. Nwosu, Alicia M. Quesnel, Adam Omari, Steven A.W. Andersen
article en

Abstract

OBJECTIVE: To determine if intraoperative inspection of patient-specific 3D-printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI). METHODS: This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra-operative inspection of a 3D-printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg-TLX) and analyzed with linear mixed-effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel-questionnaire) and prediction of intraoperative challenges. RESULTS: Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue (p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental (p = 0.01) and physical fatigue (p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity (p = 0.02) offset by higher physical fatigue (p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries. CONCLUSION: The clinical impact of intraoperative 3D-printed models during CI is modulated by surgical experience. For attendings, models act as high-fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training. LEVEL OF EVIDENCE: Level II.

The Laryngoscope
University of Copenhagen (DK), Massachusetts Eye and Ear Infirmary (US), Copenhagen University Hospital (DK), Copenhagen Academy for Medical Education and Simulation (DK)
Novo Nordisk, Novo Nordisk Fonden
Quality Education
Openalex Percentile: Top 8%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.