Interfacially coupled 2D CoS@MoS2 Heterostructures for ultrasensitive glucose detection in human urine

Advancing minimally invasive diabetes monitoring requires the development of sensitive and reliable glucose sensors that can detect glucose in biological fluids such as urine, without the need for blood sampling. Therefore, there is a growing need for glucose sensing devices that provide accurate and reliable detection while avoiding invasive blood collection. In this study, a 2D Interfacially coupled CoS@MoS₂ heterostructure was synthesized using a simple hydrothermal process and evaluated for glucose detection in human urine was investigated. The successful formation of a well-integrated CoS@MoS₂ heterointerface with enhanced electrocatalytic characteristics was confirmed through comprehensive structural, morphological, and compositional analyses using XRD, SEM, EDX, Raman spectroscopy, XPS, TEM and SAED. The CoS@MoS₂ modified GCE was found to have a rapid current response with approximately 3 s to reach a steady-state current reaction for the glucose oxidation in alkaline electrolyte. The sensor was able to show a linear response range of 0.01–0.20 mM, a very low detection limit of 1.10 nM and a high sensitivity of 915.50 μA mM −1 cm −2 under the optimized conditions. High spike-recovery results confirmed the excellent analytical accuracy, and the electrode showed good selectivity toward most urinary interferents. Moreover, glucose was successfully quantified in urine samples obtained from both diabetic and non-diabetic individuals. The CoS@MoS 2 sensor demonstrated promising performance for glucose detection in urine; however, further validation with large and more clinically diverse cohorts is necessary to establish its reliability and potential for practical applications.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2026-09-01
DOI
https://doi.org/10.1016/j.sbsr.2026.101083
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interfacially coupled 2D CoS@MoS2 Heterostructures for ultrasensitive glucose detection in human urine

Israr U. Hassan, Mustri Bano, Nouha Alcheikh, Fatima Ba Omar et al.
Sensing and Bio-Sensing Research
Electrochemical sensors and biosensors
article

Interfacially coupled 2D CoS@MoS2 Heterostructures for ultrasensitive glucose detection in human urine

Israr U. Hassan, Mustri Bano, Nouha Alcheikh, Fatima Ba Omar, Aarif H. Pinjari, Gowhar A. Naikoo
article en

Abstract

Advancing minimally invasive diabetes monitoring requires the development of sensitive and reliable glucose sensors that can detect glucose in biological fluids such as urine, without the need for blood sampling. Therefore, there is a growing need for glucose sensing devices that provide accurate and reliable detection while avoiding invasive blood collection. In this study, a 2D Interfacially coupled CoS@MoS₂ heterostructure was synthesized using a simple hydrothermal process and evaluated for glucose detection in human urine was investigated. The successful formation of a well-integrated CoS@MoS₂ heterointerface with enhanced electrocatalytic characteristics was confirmed through comprehensive structural, morphological, and compositional analyses using XRD, SEM, EDX, Raman spectroscopy, XPS, TEM and SAED. The CoS@MoS₂ modified GCE was found to have a rapid current response with approximately 3 s to reach a steady-state current reaction for the glucose oxidation in alkaline electrolyte. The sensor was able to show a linear response range of 0.01–0.20 mM, a very low detection limit of 1.10 nM and a high sensitivity of 915.50 μA mM −1 cm −2 under the optimized conditions. High spike-recovery results confirmed the excellent analytical accuracy, and the electrode showed good selectivity toward most urinary interferents. Moreover, glucose was successfully quantified in urine samples obtained from both diabetic and non-diabetic individuals. The CoS@MoS 2 sensor demonstrated promising performance for glucose detection in urine; however, further validation with large and more clinically diverse cohorts is necessary to establish its reliability and potential for practical applications.

Sensing and Bio-Sensing Research
Khalifa University of Science and Technology (AE), Swami Vivekanand College of Pharmacy (IN), Dhofar University (OM)
Good health and well-being
Openalex Percentile: Top 19%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.