The CBM Micro-Vertex Detector: Toward production readiness with MIMOSIS MAPS

The Compressed Baryonic Matter (CBM) Experiment at FAIR aims to investigate strongly interacting matter in a regime of high net-baryon density and moderate temperature using a fixed-target setup. Its Micro Vertex Detector (MVD) employs CMOS Monolithic Active Pixel Sensor (MAPS), called MIMOSIS, to achieve high-precision tracking and vertex reconstruction close to the interaction point. MAPS offer high spatial resolution, a minimal material budget, and tolerance against radiation, which makes them well-suited candidates for vertexing and tracking in the harsh CBM environment. MIMOSIS features 1024 × 504 pixels with a frame time of 5 μ s and a spatial precision of about 5–6 μ m. The sensors are required to withstand a total ionizing dose (TID) of about 5 MRad and Non-Ionizing Energy Loss (NIEL) equivalent fluences of approximately 7 × 1 0 13 n eq /cm 2 per year of CBM operation. Various prototypes have been developed through a joint R&D effort by IPHC Strasbourg, Goethe University Frankfurt and GSI Darmstadt. This contribution presents the MVD detector concept and results from radiation-tolerance measurements performed on MIMOSIS sensors. We demonstrate that AC-coupled p-stop pixel variant sustains efficiency above 99% and spatial precision of 5–6 μ m up to the combined target dose of CBM (10 14 n eq /cm 2 + 5 MRad), with the 50 μ m-thick epitaxial variant offering a wider operational threshold margin. As the 50- μ m epitaxial is not a production-standard wafer option, the 25 μ m-thick epitaxial p-stop variant is being considered for the pre-production of the MVD, which equally meets the CBM requirement.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2026-09-01
DOI
https://doi.org/10.1016/j.nima.2026.171996
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The CBM Micro-Vertex Detector: Toward production readiness with MIMOSIS MAPS

Ajit Kumar, Benedict Arnoldi-Meadows, Roma Bugiel, M. Specht et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
article

The CBM Micro-Vertex Detector: Toward production readiness with MIMOSIS MAPS

Ajit Kumar, Benedict Arnoldi-Meadows, Roma Bugiel, M. Specht, Franz Matejcek, Oliver Keller, M. Deveaux, C. Müntz, J. Baudot, Ziad El Bitar, Roland Weirich, Guy Dozière, G. Bertolone, Yüe Zhao, I. Fröhlich, Julio Andary, Ali-Murteza Altingun, J. Stroth, G. Claus, B. Gutsche, N. Bialas, Michal Koziel, M. Winter, Jan Michel, C. Colledani, Isabelle Valin, Eva-dhidho Taka, Hasan Darwish, Hung Pham, Stefan Schreiber, Christian Joachim Schmidt, Abdelkader Himmi, Andrei Dorokhov, Kimmo Jaaskelainen, Frederic Morel, Christopher Braun, Mathieu Goffe, Auguste Besson, Christine Hu-Guo
article en

Abstract

The Compressed Baryonic Matter (CBM) Experiment at FAIR aims to investigate strongly interacting matter in a regime of high net-baryon density and moderate temperature using a fixed-target setup. Its Micro Vertex Detector (MVD) employs CMOS Monolithic Active Pixel Sensor (MAPS), called MIMOSIS, to achieve high-precision tracking and vertex reconstruction close to the interaction point. MAPS offer high spatial resolution, a minimal material budget, and tolerance against radiation, which makes them well-suited candidates for vertexing and tracking in the harsh CBM environment. MIMOSIS features 1024 × 504 pixels with a frame time of 5 μ s and a spatial precision of about 5–6 μ m. The sensors are required to withstand a total ionizing dose (TID) of about 5 MRad and Non-Ionizing Energy Loss (NIEL) equivalent fluences of approximately 7 × 1 0 13 n eq /cm 2 per year of CBM operation. Various prototypes have been developed through a joint R&D effort by IPHC Strasbourg, Goethe University Frankfurt and GSI Darmstadt. This contribution presents the MVD detector concept and results from radiation-tolerance measurements performed on MIMOSIS sensors. We demonstrate that AC-coupled p-stop pixel variant sustains efficiency above 99% and spatial precision of 5–6 μ m up to the combined target dose of CBM (10 14 n eq /cm 2 + 5 MRad), with the 50 μ m-thick epitaxial variant offering a wider operational threshold margin. As the 50- μ m epitaxial is not a production-standard wafer option, the 25 μ m-thick epitaxial p-stop variant is being considered for the pre-production of the MVD, which equally meets the CBM requirement.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Goethe University Frankfurt (DE), Centre National de la Recherche Scientifique (FR), GSI Helmholtz Centre for Heavy Ion Research (DE), Université Paris-Saclay (FR), European Spallation Source (SE), Scientific Methods (United States) (US), Facility for Antiproton and Ion Research (DE), Université de Strasbourg (FR)
Deutsches Elektronen-Synchrotron
Openalex Percentile: Top 12%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.