Predictors of Dental Needle Bevel Deformation: Gauge, Insertion Frequency, and Length as Key Determinants

Background/Objectives: Dental needles are used routinely for local anaesthesia, but repeated insertion, needle selection, and operator handling may all compromise tip integrity. This study assessed bevel deformation, biological debris, and manual bending in used dental needles collected during undergraduate clinical practice. Their associations with needle dimensions, insertion frequency, injection technique, and operator seniority were also examined. Methods: 192 discarded needles were collected from fourth-, fifth-, and sixth-year students and dental interns after routine local anaesthesia procedures at an academic dental hospital. Each needle was examined under stereomicroscopy. Needle bevels were classified as intact, outward bending, or inward bending; biological debris and manual bending were also recorded. Predictors of bevel deformation were identified by multivariable logistic regression. Results: Bevel deformation was present in 93 of 192 needles. Thirty-gauge needles showed higher odds of deformation than 27-gauge needles (OR = 2.54, p = 0.004), and each additional insertion further increased the odds (OR = 1.98, p = 0.016); once gauge was accounted for, needle length was not an independent predictor. Intended bone contact showed no association with deformation. Outward bending predominated among deformed tips (63.4% vs. 36.6% inward), and biological debris was detected on 16.1% of needles. Manual bending was more frequent among interns than students (OR = 3.67, p = 0.007). Conclusions: Used dental needles frequently exhibited bevel deformation, particularly with 30-gauge needles and after repeated insertions. The occurrence of deformation even in the absence of intentional bone contact further supports strict single-use practices and careful needle handling during local anaesthesia. Although the higher frequency of manual needle bending observed among interns should be interpreted cautiously, this finding highlights a potential area for targeted operator training and further investigation.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-09-01
DOI
https://doi.org/10.3390/dj14090544
Primary Topic
Dental Anxiety and Anesthesia Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Predictors of Dental Needle Bevel Deformation: Gauge, Insertion Frequency, and Length as Key Determinants

Osama Zakaria
Dentistry Journal
Dental Anxiety and Anesthesia Techniques
article

Predictors of Dental Needle Bevel Deformation: Gauge, Insertion Frequency, and Length as Key Determinants

Osama Zakaria
article en

Abstract

Background/Objectives: Dental needles are used routinely for local anaesthesia, but repeated insertion, needle selection, and operator handling may all compromise tip integrity. This study assessed bevel deformation, biological debris, and manual bending in used dental needles collected during undergraduate clinical practice. Their associations with needle dimensions, insertion frequency, injection technique, and operator seniority were also examined. Methods: 192 discarded needles were collected from fourth-, fifth-, and sixth-year students and dental interns after routine local anaesthesia procedures at an academic dental hospital. Each needle was examined under stereomicroscopy. Needle bevels were classified as intact, outward bending, or inward bending; biological debris and manual bending were also recorded. Predictors of bevel deformation were identified by multivariable logistic regression. Results: Bevel deformation was present in 93 of 192 needles. Thirty-gauge needles showed higher odds of deformation than 27-gauge needles (OR = 2.54, p = 0.004), and each additional insertion further increased the odds (OR = 1.98, p = 0.016); once gauge was accounted for, needle length was not an independent predictor. Intended bone contact showed no association with deformation. Outward bending predominated among deformed tips (63.4% vs. 36.6% inward), and biological debris was detected on 16.1% of needles. Manual bending was more frequent among interns than students (OR = 3.67, p = 0.007). Conclusions: Used dental needles frequently exhibited bevel deformation, particularly with 30-gauge needles and after repeated insertions. The occurrence of deformation even in the absence of intentional bone contact further supports strict single-use practices and careful needle handling during local anaesthesia. Although the higher frequency of manual needle bending observed among interns should be interpreted cautiously, this finding highlights a potential area for targeted operator training and further investigation.

Dentistry JournalVol. 14(9)
Imam Abdulrahman Bin Faisal University (SA)
Openalex Percentile: Top 9%
Dental Anxiety and Anesthesia Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Predictors of Dental Needle Bevel Deformation: Gauge, Insertion Frequency, and Length as Key Determinants — Osama Zakaria · Dentistry Journal (2026) | TGRS Research Map | TGRS