Unravelling capacity fading in valve regulated lead acid battery pack for e-Rickshaw applications

This study investigates the electrical degradation behaviour of a 48 V valve-regulated lead–acid (VRLA) battery pack designed for e-rickshaw applications. The pack was subjected to continuous cycling under a severe duty profile derived from the IEC 63,193 standard, representing long-range operation under heavy load and steep-gradient driving conditions. The battery pack achieved peak performance corresponding to a maximum running time of approximately 162 min between cycles 110 and 150. However, after 164 cycles, the running time collapsed abruptly from 137 min to only 6 min, indicating sudden catastrophic failure. Several precursor warning signatures were identified prior to this collapse, including reduced charge acceptance, progressive suppression of rebound voltage, accelerated decline in energy efficiency, and a pronounced transformation of the discharge voltage profile. These degradation indicators consistently converged around the ~ 117th cycle, marking a clear inflection point at which aging transitioned from gradual to accelerated behaviour. The systematic evolution of the discharge voltage profile serve as a distinctive electrochemical fingerprint of positive active material (PAM) degradation. Based on these observations, a Dual-Regime Discharge behaviour is proposed to describe the transition from high-voltage-dominated discharge to low-voltage-dominated discharge as degradation progresses.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-14
DOI
https://doi.org/10.1038/s41598-026-75154-3
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Unravelling capacity fading in valve regulated lead acid battery pack for e-Rickshaw applications

P. Seenichamy, Sundar Mayavan, K. Arumugasamy, Nimmala Nagarjuna et al.
Scientific Reports
Battery Modeling and Management
article

Unravelling capacity fading in valve regulated lead acid battery pack for e-Rickshaw applications

P. Seenichamy, Sundar Mayavan, K. Arumugasamy, Nimmala Nagarjuna, Vandrasi Satya Prasad
article en

Abstract

This study investigates the electrical degradation behaviour of a 48 V valve-regulated lead–acid (VRLA) battery pack designed for e-rickshaw applications. The pack was subjected to continuous cycling under a severe duty profile derived from the IEC 63,193 standard, representing long-range operation under heavy load and steep-gradient driving conditions. The battery pack achieved peak performance corresponding to a maximum running time of approximately 162 min between cycles 110 and 150. However, after 164 cycles, the running time collapsed abruptly from 137 min to only 6 min, indicating sudden catastrophic failure. Several precursor warning signatures were identified prior to this collapse, including reduced charge acceptance, progressive suppression of rebound voltage, accelerated decline in energy efficiency, and a pronounced transformation of the discharge voltage profile. These degradation indicators consistently converged around the ~ 117th cycle, marking a clear inflection point at which aging transitioned from gradual to accelerated behaviour. The systematic evolution of the discharge voltage profile serve as a distinctive electrochemical fingerprint of positive active material (PAM) degradation. Based on these observations, a Dual-Regime Discharge behaviour is proposed to describe the transition from high-voltage-dominated discharge to low-voltage-dominated discharge as degradation progresses.

Scientific Reports
Central Electrochemical Research Institute (IN)
Affordable and clean energy, Industry, innovation and infrastructure
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon