Spontaneous Combustion Hazard Zoning and Ventilation Optimization in an Adjacent Goaf Considering Zonal Porosity of Narrow Coal Pillars

The degree of damage to a narrow coal pillar during mining directly affects its permeability, thereby influencing air leakage patterns and spontaneous combustion hazard areas in the adjacent goaf. However, existing studies commonly overlook zonal porosity variations caused by mining disturbances. This study focuses on the intrinsic relationship between coal pillar damage and zonal porosity. FLAC3D numerical simulation was employed to analyze the stress-displacement evolution of narrow coal pillars during mining. Based on fracture development characteristics and displacement magnitude, the pillar was divided into crushed, fracture development, and intact zones, with porosity ranges of 0.19–0.23, 0.06–0.18, and 0.01–0.05, respectively. A numerical model incorporating the adjacent goaf, narrow coal pillar, and working face was established. Using the obtained porosity parameters, air leakage pathways and spontaneous combustion hazard areas under different wind speeds were analyzed. The results indicate that crushing of the narrow coal pillar creates three distinct flow zones in the adjacent goaf: a high-ventilation velocity mainstream zone, a transitional diversion zone, and a large-scale vortex zone. As wind speed increases, the oxygen diffusion distance expands, and the spontaneous combustion hazard areas gradually enlarge. At a wind speed of 1.6 m/s, the spontaneous combustion hazard areas reach a minimum of 7,619.0 m2, accounting for approximately 6.6% of the total goaf area. The distribution of spontaneous combustion hazard areas was validated through field measurements. The proposed FLAC3D-Fluent coupled method, which incorporates zonal porosity, can accurately predict fire risks in the adjacent goaf, providing a theoretical and technical reference for fire prevention in coal mines.

Authors

Institutions

Publication Details

Journal
Combustion Science and Technology
Published
2026-09-01
DOI
https://doi.org/10.1080/00102202.2026.2725891
Primary Topic
Coal Properties and Utilization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spontaneous Combustion Hazard Zoning and Ventilation Optimization in an Adjacent Goaf Considering Zonal Porosity of Narrow Coal Pillars

Wenlong Jiao, Shurong Xu, Yi Wang, Jun Xie et al.
Combustion Science and Technology
Coal Properties and Utilization
article

Spontaneous Combustion Hazard Zoning and Ventilation Optimization in an Adjacent Goaf Considering Zonal Porosity of Narrow Coal Pillars

Wenlong Jiao, Shurong Xu, Yi Wang, Jun Xie, Xianzhong You, Dawei Chen
article en

Abstract

The degree of damage to a narrow coal pillar during mining directly affects its permeability, thereby influencing air leakage patterns and spontaneous combustion hazard areas in the adjacent goaf. However, existing studies commonly overlook zonal porosity variations caused by mining disturbances. This study focuses on the intrinsic relationship between coal pillar damage and zonal porosity. FLAC3D numerical simulation was employed to analyze the stress-displacement evolution of narrow coal pillars during mining. Based on fracture development characteristics and displacement magnitude, the pillar was divided into crushed, fracture development, and intact zones, with porosity ranges of 0.19–0.23, 0.06–0.18, and 0.01–0.05, respectively. A numerical model incorporating the adjacent goaf, narrow coal pillar, and working face was established. Using the obtained porosity parameters, air leakage pathways and spontaneous combustion hazard areas under different wind speeds were analyzed. The results indicate that crushing of the narrow coal pillar creates three distinct flow zones in the adjacent goaf: a high-ventilation velocity mainstream zone, a transitional diversion zone, and a large-scale vortex zone. As wind speed increases, the oxygen diffusion distance expands, and the spontaneous combustion hazard areas gradually enlarge. At a wind speed of 1.6 m/s, the spontaneous combustion hazard areas reach a minimum of 7,619.0 m2, accounting for approximately 6.6% of the total goaf area. The distribution of spontaneous combustion hazard areas was validated through field measurements. The proposed FLAC3D-Fluent coupled method, which incorporates zonal porosity, can accurately predict fire risks in the adjacent goaf, providing a theoretical and technical reference for fire prevention in coal mines.

Combustion Science and Technology
China University of Mining and Technology (CN), Energy Foundation (CN), Shanxi Jincheng Anthracite Mining Group (China) (CN), Shandong University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 15%
Coal Properties and Utilization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.